eng eng
REMS TDKB LS 142 × 320 × UNC 1¼
181522
REMS TDKB LS 152 × 320 × UNC 1¼
181524
REMS TDKB LS 162 × 320 × UNC 1¼
181526
REMS TDKB LS 182 × 320 × UNC 1¼
181528
REMS TDKB LS 202 × 320 × UNC 1¼
181530
Expansion anchor M12 (masonry), 10 units
079006
Knock-in anchor M12 (concrete), 50 units
079005
Flattener for knock-in anchor M12
182050
Carbide masonry drill Ø 15 mm SDS-plus
079018
Carbide masonry drill Ø 20 mm SDS-plus
079019
Fast-tightening nut set 160
079010
Fast-tightening nut set 500
183607
Knurled threaded rod M 12 x 52
079008
Fast-tightening nut
079009
Washer
079007
G ½ UDKB tapping tool for Ø 8 mm drill 180140
G ½ TDKB tapping tool for Ø 8 mm drill
180145
Carbide masonry drill Ø 8 mm
079013
Single-ended wrench SW 19
079000
Single-ended wrench SW 30
079001
Single-ended wrench SW 32
079002
Single-ended wrench SW 41
079003
Hexagon socket head wrench SW 3
079011
Hexagon socket head wrench SW 6
079004
Suction rotor for dust extraction
180160
Adapter G ½ male – UNC 1¼ male
180052
Adapter UNC 1¼ male – G ½ female
180056
Adapter UNC 1¼ male – Hilti BI
180053
Adapter UNC 1¼ male – Hilti BU
180054
Adapter UNC 1¼ male – Würth
180055
Annular core bit extension 200 mm
180155
Sharpening stone
079012
Pressurised water tank
182006
Quick-release ring
180015
Bull’s eye level
182010
Water extractor unit
183606
Rubber gasket Ø 200 mm (10 pieces)
183675
Vacuum fastening Titan
183603
Laser drilling centre pointer
183604
Spacer set (only REMS Picus SR)
183632
Drilling template Titan
183605
Vacuum pump
183670
REMS Pull L, dry and wet vacuum cleaner of dust class L
185500
REMS Pull M, dry and wet vacuum cleaner of dust class M
185501
Steel case with inlay
(REMS Picus S1, Picus S3, Picus SR)
180600 R
Steel case with inlay (REMS Picus DP)
180600 RDP
REMS CleanM
140119
1.3 Drilling depth
Useful drilling depth of the REMS Universal
diamond core drilling crown
420 mm
Useful drilling depth of the REMS dry diamond core drilling crowns 320 mm
Deeper core bore holes with crown drill extension
((50) accessory art. no. 180155) see 3.7.
1.4 Drilling range
Core drilling
steel-reinforced
masonry
operations in
concrete
and others
REMS Picus S1
≤ Ø 102 (132) mm
≤ Ø 162 mm
REMS Picus S3
≤ Ø 152 (200) mm
≤ Ø 250 mm
REMS Picus S2 / 3,5
Ø 40 – 300 mm
Ø 40 – 300 mm
REMS Picus SR
≤ Ø 162 (200) mm
≤ Ø 250 mm
REMS Picus DP
≤ Ø 162 (202) mm
≤ Ø 202 mm
Annular-bit connection thread
REMS Picus S1, Picus S3, Picus SR, Picus DP UNC 1¼ male, G ½ female
REMS Picus S2 / 3,5
UNC 1¼ male
Drill collar Ø
REMS Picus S1, Picus S3, Picus SR, Picus DP
60 mm
Drilling range with drill stand
REMS Picus S1,
Simplex 2, Titan
Ø 162 mm
REMS Picus S3,
Simplex 2, Titan
Ø 200 mm, Ø 250 mm
REMS Picus S2 / 3,5
Titan
Ø 300 mm
REMS Picus SR
Simplex 2, Titan
Ø 200 mm, Ø 250 mm
REMS Picus DP
Simplex 2, Titan
Ø 202 mm
Drilling range with vacuum fastening
REMS Picus S1, Picus S3, Picus S2 / 3,5, Picus SR
Ø 132 mm
1.5 Turning speed 230 V
Idling
At rated load
REMS Picus S1
830 min־¹
580 min־¹
REMS Picus S3
750, 1800, 2500 min־¹
530, 1280, 1780 min־¹
REMS Picus S2 / 3,5
490, 1160 min־¹
320, 760 min־¹
REMS Picus SR
250 – 1200 min־¹
250 – 1200 min־¹
REMS Picus DP
1200 min־¹
880 min־¹
REMS Picus DP micro-pulse
28800 min־¹
21120 min־¹
Turning speed 115 V
REMS Picus S1
940 min־¹
740 min־¹
REMS Picus S3
770, 1860, 2580 min־¹
570, 1380, 1920 min־¹
REMS Picus S2 / 3,5
440, 1030 min־¹
290, 680 min־¹
REMS Picus SR
250 – 1200 min־¹
250 – 1200 min־¹
REMS Picus DP
1120 min־¹
880 min־¹
REMS Picus DP micro-pulse
26880 min־¹
21120 min־¹
1.6 Electrical specifi cations 230 V
REMS Picus S1
230 V~; 50 – 60 Hz; 1850 W; 8.4 A
REMS Picus S3
230 V~; 50 – 60 Hz; 2200 W; 10.0 A
REMS Picus S2 / 3,5
230 V~; 50 – 60 Hz; 3420 W; 16.0 A
REMS Picus SR
230 V~; 50 – 60 Hz; 2200 W; 9.6 A
REMS Picus DP
230 V~; 50 – 60 Hz; 2200 W; 10.0 A
Fuse protection (mains network)
REMS Picus S1
10 A (B)
REMS Picus S3, Picus S2 / 3,5, Picus SR, Picus DP
16 A (B)
Protection class
REMS Picus S1, Picus S3, Picus S2 / 3,5, Picus SR
l
REMS Picus DP
Il
Fault-current safety switch PRCD with low-voltage release
REMS Picus S1, Picus S3, Picus S2 / 3,5, Picus SR
10 mA
Electrical specifi cations 115 V
REMS Picus S1
115 V~; 50 – 60 Hz; 1700 W; 15 A
REMS Picus S3
115 V~; 50 – 60 Hz; 2050 W; 18 A
REMS Picus S2 / 3,5
115 V~; 50 – 60 Hz; 2820 W; 25 A
REMS Picus SR
115 V~; 50 – 60 Hz; 2200 W; 19 A
REMS Picus DP
120 V~; 50 – 60 Hz; 2050 W; 18 A
Fuse protection (mains network)
REMS Picus S1
20 A (B)
REMS Picus S3, Picus S2 / 3,5, Picus SR, Picus DP
25 A (B)
Protection class
REMS Picus S1, Picus S3, Picus S2 / 3,5, Picus SR
l
REMS Picus DP
Il
Fault-current safety switch PRCD with low-voltage release
REMS Picus S1, Picus S3, Picus S2 / 3,5, Picus SR
6 mA
1.7 Dimensions (L × W × H)
REMS Picus S1
450×170×100 mm (17.7"×6.7"×3.9")
REMS Picus S3
550×170×105 mm (21.6"×6.7"×4.1")
REMS Picus S2 / 3,5
490×205×150 mm (19.3"×8.1"×5.9")
REMS Picus SR
590×145×110 mm (23.2"×5.7"×4.3")
REMS Picus DP
565×170×100 mm (22.2"×6.7"×3.9")
REMS Simplex 2, drill stand
435×245×805 mm (17.1"×9.6"×31.7")
REMS Titan, drill stand
360×555×1050 mm (14.2"×21.8"×41.3")
1.8 Weights
REMS Picus S1
5.2 kg (11.5 lb)
REMS Picus S3
7.4 kg (16.3 lb)
REMS Picus S2 / 3,5
14.4 kg (31.7 lb)
REMS Picus SR
6.4 kg (14.1 lb)
REMS Picus DP
7.0 kg (15.4 lb)
REMS Simplex 2, drill stand
12.0 kg (26.4 lb)
REMS Titan, drill stand
19.5 kg (43.0 lb)
1.9 Noise emissions
Sound pressure
Operating sound
level L
PA
level L
WA
REMS Picus S1, Picus S3
90 dB(A)
103 dB(A)
REMS Picus S2 / 3,5, Picus SR
91 dB(A)
104 dB(A)
REMS Picus DP
99 dB(A)
110 dB(A)
Uncertainty K
3 dB(A)
3 dB(A)
1.10 Vibrations
Weighted effective value of acceleration
REMS Picus S1, Picus S3, Picus S2 / 3,5, Picus SR
2.5 m/s²
REMS Picus DP with micro-pulse technology, free-hand
17.5 m/s²
REMS Picus DP with micro-pulse technology, with drill stand
4.8 m/s²
Uncertainty K
1.5 m/s²
The indicated weighted effective value of acceleration has been measured
against standard test procedures and can be used by way of comparison with
another device. The indicated weighted effective value of acceleration can also
be used as a preliminary evaluation of the exposure.
CAUTION
CAUTION
The indicated weighted effective value of acceleration can differ during opera-
tion from the indicated value, dependent on the manner in which the device is
used. Dependent upon the actual conditions of use (periodic duty) it may be
necessary to establish safety precautions for the protection of the operator.