214
2.7.2 Wiring the Terminal Strip
The terminal strip on the Regulator board provides terminals for connecting customer I/O devices.
See figures 2.8, 2.9, and 2.12. The following terminals are provided:
D
Terminals 13: RS232 connections
D
Terminals 49: pulse tachometer connections
D
Terminals 1011: analog output connections
D
Terminals 1215: analog speed/torque reference connections
D
Terminals 1625: 24V DC digital input connections (160 HP Regulator boards only)
D
Terminals 2627: snubber resistor braking control connections (160 HP Regulator boards only)
D
Terminals 2831: status relay connections
WIRES BETWEEN TERMINALS 16+16A AND
20 + 20A ARE NECESSARY FOR PROPER
OPERATION OF THE FUNCTION LOSS
INPUT. THEY SHOULD NOT BE REMOVED.
PULSE TACHOMETER
CONNECTIONS
PHASE B NOT
DIGIT
AL INPUT 8 (REMOTE/LOCAL)
DIGIT
AL INPUT 7 (RAMP1/RAMP2)
DIGIT
AL INPUT 6 (FOR
W
ARD/REVERSE)
FACTORY
INSTALLED
Figure 2.12 Typical Terminal Strip Connections