79
Table 7.1 Wiring Signal and Control I/O to the Terminal Strip (Continued)
ÁÁÁÁÁ
Á
ÁÁÁ
Á
ÁÁÁÁÁ
Terminal
Number
ÁÁÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁÁÁ
Description
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Parameters/Wiring Connections
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Wiring Analog Speed Reference Inputs
12
13
14
15
Isolated Reference
Voltage (+15VDC)
Analog Speed/Torque
Reference Input Voltage
(+/- 10 VDC)
Analog Speed/Torque
Reference Input Current
(020mA)
Isolated Speed/Torque
Reference Common
(Voltage/Current)
The following parameters must be set:
P.000: Control Source
P.009: Terminal Strip Analog Input Offset
P.010: Terminal Strip Analog Input Gain
P.011: Terminal Strip Analog Input Invert
Refer to the GV3000 Programming instruction manual
(D23339) for additional parameter information.
Jumper J4 must also be set. See figure 2.10.