Wiring an Additional Ramp Input
18
Digital Input 7
(Default Ramp1/Ramp2)
Digital input 7 is control function programmable through
parameter P.007. The following parameters must be set:
P.000: Control Source
P.001: Accel Time 1 (Ramp 1)
P.002: Decel Time 1 (Ramp 1)
P.006: Second Menu Password
P.007: Terminal Strip Digital Inputs Configure (Selects
and assigns a control function to digital inputs
6 to 8).
P.008 Terminal Strip Speed Reference Source (Analog,
Motor Operated Potentiometer (MOP), or
Preset Speeds)
P.017: Accel Time 2 (Ramp 2)
P.018: Decel Time 2 (Ramp 2)
Note that based on the settings of parameters P.000, P.007,
P.008, and r.030 if an RMI board is used, the following
parameters can affect digital input 7.
P.023: MOP Accel/Decel Time
P.024: MOP Reset Configuration
P.031 to P.038: Preset Speeds 18
Refer to the GV3000 Programming instruction manual
(D23339) for additional information.
Terminal 18 On = Ramp 2
Diagram shows factory setting.