9
User menu is comprised of:
•
zone 1
•
zone 2
•
DHW zone
•
DHW recircul.
•
time program (time programs)
•
OTC Curves
•
operation data (temperatures and outputs condition)
•
time, date
•
other (adjusting other parameters)
•
SMS settings (automatic text messaging)
•
heat measurement (heat measured between two sensors)
The keys
,
enable browsing, and the selected item can be entered by pressing
OK.
2.1 Heating zones
In this Menu, a user can adjust these parameters:
zone on
switching on the zone on the User level. When a zone gets switched off on
this level, also the circulation pump and valve outlets switch off as well. The
pump and valve outlets can be activated by frost protection function if it is on.
In this controller version, switching off zone 1 will switch off zone 2 as well!
Mode Auto will activate the summer/winter mode.
T comfort
setting comfort temperature in zone. This parameter makes sense only when
a room sensor is used.
T setback
setting setback temperature in zone. This parameter makes sense only when
a room sensor is used.
Note: During a day, the controller switches the desired zone temperatures
between T day and T night by the preset time schedule.