![Regulus IR 12 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/regulus/ir-12/ir-12_user-manual_1434395037.webp)
37
fireplace temp. to start pump (°C)
Setting the temperature of water outgoing from
fireplace above which the fireplace circulation pump
starts.
max. Thermal Store temp (°C)
The max. Thermal Store temperature for the fireplace
function. When this temperature is exceeded, the fire
pump is turned off.
temp.diff.to ON (°C)
Switch-on difference to start the fire pump, i.e. fireplace temp. above
the Thermal Store Lower value.
temp.diff.to OFF (°C)
Switch-off difference for the fire pump.
S 2.8 – Other service parameters
new passw
Setting a numeric code for access to Service level of menu.
website password reset (yes/no) Selecting yes will reset the password and username for
controller website access to the default values.
Frost protection:
When Frost protection is on, the temperature is monitored for a switched off zone. Should the
outdoor temperature drop below the value set in parameter
out. temp.
, then the heating
water temperature is kept at value set by parameter
water temp.
.
Содержание IR 12
Страница 1: ...EN ver 1 9 IR 12 Heating Controller Users Guide Ver IR12_KRB Valid for FW 4 01...
Страница 51: ...51 RegulusRoute yes no Enabling RegulusRoute service status Service state...
Страница 54: ......
Страница 55: ......