S 2.9 – Temperature Sensor Management
The temperature measured by the Controller may differ from a real temperature due to
defects. The measured value may be affected e.g. by the preciseness of the temperature
sensor, the length and cross section of the cable used for sensors, by the quality of contact
between the temperature sensor and the medium measured. The temperature data can be
adjusted by offset in the range from -9.0 to +9.0 °C.
connected “No“ option shall be selected in case no temperature sensor is connected (to avoid the
program reporting an error when the sensor is disconnected). The default option is
“Yes”.
adjustment Temperature sensor offset.
state
The sensor state – if the sensor is in an error state (either a too high or a too low
temperature is sensed), the text fault is displayed.
S 2.10 – Universal Outputs
The universal output 1 (uni1) – the F3 terminal can be used to control a diverter valve for
solar tank No. 3 (option div.v.sol3), control a DHW recirculation pump (option circulat.),
control a heating zone 1 circulator (option zone 1 pump), or it may be used as a universal
thermostat (option thermostat).
Eventually the universal output can be switched off completely. The universal output 2 (uni2)
– the E4 terminal can be used to control heating zone 2 circulator (option zone 2 pump) or it
can be used as a universal thermostat (option thermostat). Eventually the universal output
can be switched off completely.
uni1
Selection of the universal output type (cf. above).