Thermostat 1/2 is set in Heating mode. When Timer function is also On, the
request will be taken over during active time period only.
Differential thermostat:
differential thermostat function between sensors 1 and 2
on/off (on/off)
Switching differential thermostat function on/off.
diff. on (°C)
Switch-on difference between temperatures t1 and t2.
diff. off (°C)
Switch-off difference between temperatures t1 and t2.
Delay:
output delay function
on/off (on/off)
Switching the delay function on/off.
period (minutes)
Delay time in case when all the preceding functions are fulfilled.
Overrun:
overrun function (output delayed switch-off)
on/off (on/off)
Switching the overrun function on/off.
overrun (minutes) Overrun time after the preceding functions are switched off.
Timer:
timer functions with two time periods