schedule defines from-to operation times. For this period, circulation time and idle time can
be set if continuous operation is not desired. E.g. Monday from 6.00 a.m. to 10.30 p.m. the
recirculation pump will always run for 10 min. and then idle for 15 min.
on (off / on)
recirculation switched on.
circ. time (min)
circulation time setting.
idle time (min)
idle time setting.
circulation times time setting for separate days when recirculation is on (7 displays – Monday to
Sunday).
2.4 Time programs
Time programs can be set either for separate days, or in blocks Mo-Fr and Sa-Su.
When the program is being set for separate days, there are 2 transitions from Comfort to
Setback and 2 from Setback to Comfort for each day.
When the program is being set in blocks, there are similarly 2 transitions from Comfort to
Setback and 2 from Setback to Comfort for the blocks Mo-Fr and Sa-Su. Answering YES to
the question Copy program? will rewrite the respective time program blocks.
If program copying is not desired, let the question be with no and leave the menu by pressing
C.