NATURAL GAS FIREPLACE INSERT:
MODEL HRI4E-NG11
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. supply pressure
5“
WC
(1.25 kpa)
Low Setting Man. pressure
1.6"
WC
(0.41 kpa)
Max. Manifold pressure
3.5"
WC
(0.87 kpa)
Orifice size
#37
DMS
Minimum input
22,000
Btu/h (6.45 kW)
Maximum input
31,000
Btu/h (9.09 kW)
PROPANE GAS FIREPLACE INSERT:
MODEL HRI4E-LP11
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. supply pressure
11"
WC (2.73 kpa)
Low Setting Man. pressure
6.4"
WC (1.59 kpa)
Max. Manifold pressure
10"
WC (2.48 kpa)
Orifice size
#53
DMS
Minimum input
26,000 Btu/h (7.62 kW)
Maximum input
31,000 Btu/h (9.09 kW)
Model/Modèle:
HRI4E-NG1
1
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ÉTIQUETTE
Serial No. / No de série
486
486
Duplicate Serial number
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and
Propane Installation Code, CSA B149.1.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases unless a certified kit is used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured
(mobile) home where not prohibited by local codes. See owner's manual for details
WARNING. This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original
parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel
Gas Code ou CSA-B149.1 en vigueur.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique.
Cet appareil n'est pas convertible pour être utilisé avec d'autres gaz, sauf si une trousse de conversion certifiée est utilisée.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique et peut être installé dans une maison préfabriquée ou
mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir le manuel d'utilisation pour plus de renseignements. Cet
appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
AVERTISSEMENT : Ce foyer a été converti pour être utilisé avec un foyer au gaz encastrable et ne peut être utilisé pour brûler du bois ou d'autres
combustibles solides à moins que toutes les pièces d'origine aient été remises en place et que le foyer ait été homologué de nouveau par une autorité
compétente.
This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
For use with glass doors certified with the appliance only. Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil.
o
For use only with barrier (Part # 399-100) Follow installation instructions. Pour l'utilisation seulement avec l’écran de sécurité (Pièce n 399-100)
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS. /
FOYER AU GAZ VENTILÉ - NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.
Model/Modèle:
HRI4E-
LP1
1
MODÈLE HRI4E- LP11
FONCTIONNANT AU GAZ PROPANE
MODÈLE HRI4E- NG11
FONCTIONNANT AU GAZ NATUREL
Pression d'alimentation minimale
Pression de sortie (manifold)
-
basse
Pression de sortie (manifold)
-
max.
Taille de l'orifice
D bit calorifique minimal
é
D bit calorifique maximal
é
Pression d'alimentation minimale
Pression de sortie (manifold)
-
basse
Pression de sortie (manifold)
-
max.
Taille de l'orifice
D bit calorifique minimal
é
D bit calorifique maximal
é
Min. Hearth Width
D 14” (356mm)
Min. Hearth Length E 40” (1016mm)
Max. Mantle Depth
G 12" (305mm)
.
Mantel Clearances/
Dégagements manteau
Side wall
A 8”
(203mm)
Ceiling
B 60"
(1524mm)
Mantel
C 35”
(889mm)
Min. Alcove Width
K 54"
(1372mm)
Max. Alcove Depth
L 36”
(914mm)
Regency Fireplace Products,
Delta BC, CANADA
A
B
E
K
D
L
G
MADE IN CANADA /FABRIQUÉ AU CANADA
Minimum Clearances to Combustibles
from Insert
C#4001172
This appliance is only for use with the type of gas indicated on the rating
plate and may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la
plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les
règlements locaux le permettent. Voir la notice de l'utilisateur pour plus
de renseignements.
Electrical supply / Électrique 115VAC, 2.5 A, 60Hz.
Electrical supply / Alimentation électrique 115VAC, 2.5 A, 60Hz, Less than 10A
Fan/Ventilateur Part # 911-071
A
C
B
E
K
D
L
G
Part #:
919-935a
Colour: Black on grey except what is highlighted is printed red
Size:
(File at 100%) 6.688’’W x 8.588’’H
Material:
2 ml silver matt polyester (DPM SMS)
Oct.15/2018:
Created draft
Nov.05/18:
New Serial #
Jan.14/19:
Updated effici orifice size #
Jan 23/19:
Rev A - Remodeled decal + added ETL logo at the bottom
Listed/Nom:
VENTED GAS FIREPLACE HEATER /
FOYER AU GAZ VENTILÉ
Certified to / Certifi :
é
ANSI Z21.88-2017 • CSA-2.33-2017
CSA 2.17-2017
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek.
919-935a
CSA P.4.1 Fireplace Efficiency (FE) /Efficacité énergétique des foyers (EEF) CSA P.4.1
Natural Gas / Gaz naturel 70.27%
Propane Gas / Gaz propane 69.36%
CANADIAN ENERGY
PERFORMANCE
VERIFIED
RENDEMENT
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
For the State of Massachusetts, installation and repair must be done by a plumber or gas fitter licensed in the Com-
monwealth of Massachusetts.
For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and
a CO alarm with battery back up in the same room where the gas appliance is installed.
COPY OF SAFETY LABEL
Содержание Liberty LRI4E series
Страница 62: ...62 LRI4E HRI4E 11 Direct Vent Gas Insert parts list 12 ...
Страница 65: ...LRI4E HRI4E 11 Direct Vent Gas Insert 65 notes ...
Страница 70: ...70 LRI4E HRI4E 11 Direct Vent Gas Insert warranty ...
Страница 71: ...LRI4E HRI4E 11 Direct Vent Gas Insert 71 ...