2 |
LRI4E / HRI4E-11 Direct Vent Gas Insert
TO THE NEW OWNER
Congratulations! You are the owner of a state-of-the-art Gas Insert by Regency.
The Regency Gas Insert Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a fireplace, at
the flick of a switch. The models LRI4E / HRI4E of this series have been approved by Warnock Hersey/Intertek for both safety and efficiency.
As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
Please take a moment now to acquaint yourself with these instructions and the many features of your
Regency Fireplace.
Horizon HRI4E
Liberty Gas
Inserts Benefits
Horizon Gas
Inserts Benefits
Liberty LRI4E
ON DEMAND PILOT LIGHT
(SEVEN DAY SAFETY TIMER)
Important information if using the appliance in CPI (continuous pilot mode) only.
This appliance is a ProFlame 1 system fitted with the “On Demand” Pilot, a safety feature which will shut down the gas valve com-
pletely by extinguishing the pilot light in the event of a continuous full seven days of inactivity.
This only applies if the CPI (continuous pilot) switch is in the “on” position.
Each time the main burner shuts down, manually or through the call from the thermostat, the seven day timer starts again.
The seven day inactivity timer is controlled within the circuit board. Therefore, if in CPI mode and when the pilot light is extinguished
after seven straight days of inactivity, the IPI/CPI rocker switch will remain in the “on” position. Therefore, all that is required to relight
the pilot would be to press the on/off button on the remote control transmitter from “on” to “off” and back to “on”. Once the pilot has
re-established operation will resume as normal. There is no requirement to do anything with the IPI/CPI rocker switch.
If the unit never goes as long as seven full days without a call for heat, the pilot will remain lit until it is manually shut-off.
If the unit is being operated in IPI (intermittent pilot) mode, neither the above instructions nor the seven day timer will apply.
See the instructions in this manual and on the Lighting Instructions plate on the appliance to light or re-light the pilot.
Содержание Liberty LRI4E series
Страница 62: ...62 LRI4E HRI4E 11 Direct Vent Gas Insert parts list 12 ...
Страница 65: ...LRI4E HRI4E 11 Direct Vent Gas Insert 65 notes ...
Страница 70: ...70 LRI4E HRI4E 11 Direct Vent Gas Insert warranty ...
Страница 71: ...LRI4E HRI4E 11 Direct Vent Gas Insert 71 ...