LRI3E / HRI3E Direct Vent Gas Insert
|
41
|
41
maintenance
8. Remove the back delector by removing 4 top screws and loosening 2
bottom screws.
9. Remove the valve access plate by removing 11 screws on the side panel
and 3 on the bottom as shown below.
tooltip
10. Lift out panel (part of valve assembly) with valve and pilot assembly.
Diagram 7
Diagram 8
Diagram 9
11. Replace with new valve assembly, ensuring to use a new gasket before
securing new valve access plate to unit.
12. Reassemble unit by reversing Steps 8-1.
13. Reconnect the gas and electrical supply to the unit. Once the unit has
been reired, use a soapy water mixture to check all itting and gas sup-
ply lines for gas leaks.