background image

5109212/03

INSTALLER GUIDE

Because our policy is one of constant development and improvement, details

may vary slightly from those given in this publication.

INSTALLER: Please leave this guide with the 

owner 

THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20)

THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED

KINGDOM (GB) AND THE REPUBLIC OF IRELAND (IE). 

© Valor Heating

Equinox

INSET LIVE FUEL EFFECT GAS FIRE

Model 754

(GC No. 32-032-59)

Manufactured exclusively for British Gas & Scottish Gas by Valor Heating

For Service Phone 0845 950 0400

Содержание Equinox 754

Страница 1: ...se leave this guide with the owner THIS APPLIANCE IS FOR USE WITH NATURAL GAS G20 THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED KINGDOM GB AND THE REPUBLIC OF IRELAND IE Valor Heating...

Страница 2: ...s a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation The manufacturer is a CORGI registered company This gas...

Страница 3: ...ONT SURROUND INSTALLATION 29 13 CERAMIC PEBBLES INSTALLATION 31 14 FULL OPERATING CHECKS 34 14 1 Check the Control Settings 34 14 1 1 Lighting the burner 34 14 1 2 Operating the burner 34 14 2 Check F...

Страница 4: ...nd not your back Avoid twisting at the waist It is better to reposition your feet Avoid upper body top heavy bending Do not lean forward or sideways whilst handling the fire Always grip with the palm...

Страница 5: ...waste This is not classified as hazardous waste and may be disposed of at a tipping site licensed for the disposal of industrial waste Protective clothing is not required when handling these articles...

Страница 6: ...o be in accordance with All the relevant parts of local regulations All relevant codes of practice The relevant parts of the current editions of the following British Standards BS 715 BS 1251 BS 1289...

Страница 7: ...th BS1251 after removal of the fireback and sufficient material behind the fireback for a debris catchment space The required fireplace hearth debris catchment area and clearance dimensions are shown...

Страница 8: ...that faults such as cracking may be caused by poorly built and restrictive flues e g mortar extrusions too many bends flue heights below three metres restrictive terminations etc 4 2 4 If the firepla...

Страница 9: ...must not be used for any other appliance or application 4 6 Any chimney damper or restrictor should be removed If removal is not possible they must be secured in the open position 4 7 If the applianc...

Страница 10: ...top surface of the hearth to the underside of any shelf made from wood or other combustible materials is shown below For a shelf up to 150mm deep Minimum height 700mm For a shelf deeper than 150mm Min...

Страница 11: ...tion is available 4 16 If the appliance is to be fitted against a wall with combustible cladding the cladding must be removed from the area covered by the outer surround The cladding must also not tou...

Страница 12: ...consumer should be informed to stop using the appliance until the installation and appliance have been thoroughly checked The A S D will shut the appliance down if an unacceptable amount of harmful pr...

Страница 13: ...Page 13 INSTALLER GUIDE...

Страница 14: ...Ceramic support rods 2 Small U seals for hotbox side flanges 1 Strip of floor sealing tape 6 Fibre plugs 4 Woodscrews 2 Fire retaining cables 2 Cable clamps 4 Eyebolts 1 Rubber grommet 1 Smoke match t...

Страница 15: ...Page 15 INSTALLER GUIDE Figure 6 Pack contents...

Страница 16: ...ing must be removed from the area covered by the outer surround The cladding must also not touch the surround See figure 4 We suggest that the actual surround is used as a template to mark the area fo...

Страница 17: ...l or equivalent insulation See figure 2 6 2 Fireplace Flue Pull Close all doors and windows in the room in which the appliance is to be installed After confirming with a match that smoke is drawn into...

Страница 18: ...ector can be rotated to allow a connection from any direction The T connector includes a valve for isolating the gas supply and a pressure test point The supply pipe must be rigid material Flexible pi...

Страница 19: ...ner reflector See figure 10 4 Carefully lift the inner reflector and pull forward to remove Be careful not to scratch the top surface of the burner cover See figure 10 The reflector may spring a littl...

Страница 20: ...section seals to the bottom edges of the hotbox side flanges See figure 12 11 It is important that the grommet supplied in the loose parts pack is fitted to the hole in the rear of the convection box...

Страница 21: ...the two supplied with the fire 14 This appliance is supplied with a flue restrictor for use where the flue draught is excessive The restrictor must NOT be fitted where a precast flue or a flue liner i...

Страница 22: ...seal Be careful not to stretch the seal when measuring Remove the protective backing from the foam seal and fit this to the rear of the top flange See figure 15 Cut two 580mm lengths Fit these to the...

Страница 23: ...hotbox into the fireplace feeding the supply pipe through the pierced hole in the rear grommet 3 Mark the fireplace front surround through the four fixing holes in the side flanges of the hotbox See...

Страница 24: ...opening when tension is applied to the cables 3 Insert a fibre plug into each hole Use the fibre plugs supplied with this appliance Never use plastic plugs instead of the fibre plugs supplied Screw th...

Страница 25: ...se of the hotbox using a no 12 masonry drill See figure 20 9 Insert a fibre plug into each hole Use the rawlplugs supplied with this appliance Never use plastic plugs instead of the fibre plugs suppli...

Страница 26: ...y tension to the cables by turning the hexagonal adjusters clockwise as far as possible 14 Feed the free length of the cables into the gap between the inner and outer back panels so that they are avai...

Страница 27: ...or isolating the gas supply The supply pipe must be rigid material Flexible pipe must not be used Connect the supply line to the appliance Turn on the gas supply and pressure check the installation pi...

Страница 28: ...ol knob depressed and hold the pilot ignition position for five seconds When the control knob is released the pilot flame should remain lit If there are no sparks check that the electrode lead is conn...

Страница 29: ...the maximum output position and test around the sealing screw for gas soundness with a suitable leak detection fluid 12 FRONT SURROUND INSTALLATION 1 Remove any protective film from the front surround...

Страница 30: ...3 2 The trim sections are held in place using 8 magnets Position the magnets as in figure 26 Note that the magnets on the bottom and top trim are inside of the cutout This will ensure that the bottom...

Страница 31: ...front base pebble in front of the burner See figure 30 2 The rear base pebble has the letters MB on the underside Locate the rear base pebble behind the burner See figure 31 Page 31 INSTALLER GUIDE F...

Страница 32: ...te the second pebble 5 centrally between the right hand ceramic support rods See figure 33 They will now be positioned directly above the burner ports 5 Pebble 3 has a location peg on the underside Th...

Страница 33: ...t rods See figure 36 Leave a gap between pebble 3 and the pebble 1 This will allow the pilot flame to be viewed 8 There are two pebbles numbered 2 on the underside Locate these on the pebble base betw...

Страница 34: ...to the pilot ignition position A click will be heard as the integral piezo operates A flame should appear at the pilot to the left hand side of the pebble base When a flame appears at the pilot keep...

Страница 35: ...ue restrictor See section 9 point 14 remove the restrictor reseal the appliance and retest If smoke is still not drawn into the appliance disconnect the appliance and seek expert advice 5 If the above...

Страница 36: ...re surface Front surround Clean the metal parts with a slightly damp cloth and then dry If this does not work apply a very small amount of baby oil to a lint free non abrasive cloth and wipe over the...

Страница 37: ...an isolating valve It is recommended that at least once a year the appliance is disconnected and the fireplace opening checked and cleared of any debris This product uses fuel effect pieces containing...

Страница 38: ...move the upper surround trim lower surround trim and side surround trims These are held by magnets 2 The surround is held in place by four retaining plates at the back of the surround These slot into...

Страница 39: ...r to avoid straining the pipework and disconnect the appliance from the T connector 10 Detach the burner unit from the hotbox by lifting clear 11 Replace in the reverse order 16 3 To Remove the Pilot...

Страница 40: ...gas valve to the mounting bracket 10 Remove the gas valve 11 Refit in the reverse order 16 5 To Remove the Piezo Generator 1 Remove the gas valve as section 16 4 2 Make sure that the tap is in the of...

Страница 41: ...from the burner clamping plate See figure 46 4 Lift the right hand side of the burner slide it to the right and lift clear 5 Refit in reverse order 16 8 To Remove the Main Burner Injector See figure...

Страница 42: ...EY DESCRIPTION NO OFF PART NO A Control valve spark generator 1 5108221 B Spark generator and circlip 1 5108923 C Pilot unit 1 3002988 D Injector Stereomatic Cat 82 065 1 5108138 E Burner 1 5108827 F...