7. IGNITION CHECK
Before attempting to install, it is worth checking that
the ignition system performs satisfactorily.
Set the control knob to the off position.
Depress the control knob and rotate it anticlockwise
to the pilot ignition position. A 'click' will be heard
as the integral piezo operates. A spark should be seen
between the electrode and pilot tip
.
If there is no
spark check the following: -
Ensure that the electrode lead is connected to the
terminal at the base of the electrode.
If the above is correct, check for damage to the
electrode lead.
8. GAS SUPPLY CONNECTION
A nut and olive are provided for an 8mm pipe inlet connection to the ‘T’ connector at
the bottom front of the appliance. The ‘T’ connector can be rotated to allow a
connection from any direction. The ‘T’ connector includes a valve for isolating the gas
supply and a pressure test point.
The supply pipe must be rigid material. Flexible pipe must not be used.
Concealed Supply Pipe Connection
If a concealed connection from inside the fireplace is required then
,
before the
appliance is fitted into the fireplace
it will be necessary to extend the supply line so
that it will project through the hole in the back of the hotbox and run to the ‘T’
connector at the front. The pipe run from the supply line up to the rear opening in the
hotbox must be kept away from the area which will be taken by the hotbox when it is
installed. Note that the centre of the appliance inlet ‘T’ connector is 25mm above the
fireplace floor. The inlet ‘T’ connector should be fitted to the supply pipe at this stage.