the Environment for Northern Ireland.
In the republic of Ireland the installation must also conform to the relevant parts of:
a)
The current edition of IS 813 “Domestic gas installations”
b)
All relevant national and local rules in force.
Where no specific instructions are given, reference should be made to the relevant
British Standard Code of Practice.
4.2
In the United Kingdom, as supplied, the appliance can be installed in the following
situations: -
4.2.1
To a fireplace complete with surround and hearth as shown in figure 1 and
complying with BS1251 after removal of the fireback and sufficient material behind the
fireback for a debris catchment space. The required fireplace, hearth, debris catchment
area and clearance dimensions are shown in figure 1.
4.2.1.1 ‘Hole-in-the-wall’ Installations
It is recommended that a hearth should be installed as in figure 1.
If a hearth is not fitted, the fire must be installed so that the distance from the base
of the fireplace opening in the wall to the finished floor level is at least 85mm.
4.2.2
To a fireplace
incorporating a metal flue box
complying with the
constructional requirements of
the current edition of BS715.
The dimensions of the flue box
must conform to those shown
in figure 2.
Page 7
INSTALLER GUIDE
Figure 2. Metal Flue Box