background image

10

 | 

LRI3E / HRI3E Direct Vent Gas Insert

 | 

10

installation

General Safety Information

1)

  The appliance installation must conform with 

local codes or in the absence of local codes, 
with CAN/CGA B149 (in Canada) or the National 
Fuel Gas Code ANSI Z223.1 in the U.S.A. This 
appliance should be installed by a qualiied gas 
itter technician only.

2)  Installation and repair should be done by a 

qualiied service person.  

3)

  The  appliance should be inspected before use 

and at least annually by a professional service 
person. More frequent cleaning may be required 
due to excessive lint from carpeting, bedding 
material, animal hair, etc.  It is imperative that 
control compartments, burners and circulating 
air passageways of the appliance be kept clean. 

4)

  See  general  construction  and  assembly 

instructions.  This  appliance  may  only  be 
installed in a vented, noncombustible ireplace.

5)

  This appliance is listed for bedroom  installations 

when  used  with  a  listed  Millivolt Thermostat. 
Some  areas  may  have  further  requirements, 
check local codes before installation.

6)

  Always  connect  this  insert  to  a  vent  system 

venting to the outside of the building envelope. 
Never vent  to another room or inside a building.  
Make sure that the vent is properly sized and is 
of adequate height to provide the proper draft.  

7)

  Inspect the venting system annually for blockage 

and any signs of deterioration.   

8)

  Any  glass  removed  for  servicing  must  be 

replaced prior to operating the appliance.  

9)

  To prevent  injury, do not allow anyone who is 

unfamiliar with the operation to use the ireplace.

10)

 This appliance cannot be operated without brick 

or enamel panels in place.

11) 

Due to high temperatures, the appliance should 
be located out of high trafic areas and away 
from  furniture  and  draperies.  Children  and 
adults should be alerted to the hazards of high 
surface temperatures, especially the ireplace 
glass and gold trims, and should stay away to 
avoid burns or clothing ignition. Young children 
should be carefully  supervised when they are 
in the same room as the appliance. Clothing or 
other lammable material should not be placed 
on or near the appliance.

Emissions from burning  wood or gas could 
contain  chemicals  known  to  the  State  of 
California to  cause cancer, birth defects 
or other reproductive harm.

GAS PRESSURE  
TESTING

The appliance must be isolated from the gas sup-
ply piping system by closing its individual manual 
shut  off  valve  during  any  pressure  testing  of  the 
gas supply piping system at test pressures equal 
to or less than 1/2 psig. (3.45 kPa).

INSTALLATION INTO A SOLID FUEL 
BURNING FIREPLACE OR FACTORY 
BUILT FIREPLACE

The LRI3E / HRI3E  Gas Inserts have been tested 
and approved to be vented into any masonry ire-
place or  approved solid fuel burning factory built 
ireplace that will allow the insert to physically it into 
the irebox. Refer to "Minimum  Fireplace Dimen-
sions" section for minimum ireplace clearances.

If  the  factory  built  ireplace*  height  is  too  low  for 
your  Insert,  you  may  remove  the  smoke  bafle 
plate, damper, refractory (irebricks), glass doors, 
screen rails, screen mesh and log grates from the 
factory built ireplace as long as these items are 
saved and are reinstalled in the event that the Insert 
is removed. The ireplace lue damper can be fully 
blocked open or removed for installation of the gas 
ireplace insert.

Smoke shelves, shields and bafles may be removed 
if attached by mechanical fasteners. If any part is 
removed it must not weaken the structural integrity 
of the factory built ireplace.

The ireplace and ireplace chimney must be clean 
and in good working order and constructed of non- 
combustible materials.

The  surround  panels  should  not  seal  ventilation 
openings on the ireplace.

Chimney clean outs should it properly.

NOTE

: Any alterations made to the listed solid fuel 

burning factory built ireplace may void the listing 
of the ireplace.
Cutting  any  sheet  metal  part  of  the  ireplace,  in 
which the gas ireplace insert is to be installed  is 
prohibited.
*Check with your local inspector before commencing 
with this installation.

Installer  must  mechanically  attach  the  supplied 
label to the inside of the irebox of the ireplace into 
which the gas ireplace insert is installed.

"

WARNING

:  This  ireplace  has  been  converted 

for use with a gas ireplace insert only and cannot 
be used for burning wood or solid fuels unless all 
original parts have been replaced, and the ireplace 
re-approved by the authority having jurisdiction."

FACTORY-BUILT (METAL) WOOD-
BURNING FIREPLACE  
REQUIREMENTS

NOTE

: Any parts that are removed must be removed 

in a way that would allow them to be re-installed if
the  insert  is  ever  removed  (removal  of  rivets  or 
screws is acceptable).

To reference parts—see illustration below.

Must

 be removed:

1

 -Damper

2

- Grate (with log set)

May be removed (if applicable):

3

- Smoke shelf

4

- Internal bafles

5

 - Screen

6 & 7

 - Masonry lining or refractory

8

 - Metal or glass doors

The  ireplace  must  be  permanently  marked  to 
indicate that it has been altered and is no longer 
suitable  for  burning  solid  fuel  (wood),  unless  the 
removed parts are re-installed. Cutting of any sheet 
metal parts is prohibited.

May be removed (in certain cases):

9

 -Metal loor of the irebox

10

 - The insulation and any structured rigid frame

members must not be removed or altered (side and
top of door frame, side and top of the face of the
ireplace, metal sides, etc.).

If  the  factory-built  ireplace  has  no  gas  access 
hole(s) provided, an access hole of 1.5 inch (37.5 
mm) or less may be drilled through the lower sides 
or bottom of the irebox in a proper workmanship 
like manner. This access hole must be plugged 
with  non-combustible  insulation  after  the  gas 
supply line has been installed.

CAUTION: 

Firebox loor removal is not covered under the 
appliance safety standard (ANSI Z21.88, CSA 
2.33) used in the safety certiication of this ap-
pliance.  The  Intertek  safety  certiication  does 
not apply to this method of installation. Before 
installing the appliance using this method, contact 
the  Authority  Having  Jurisdiction  to  determine 
if  this  installation  is  acceptable  in  your  area. 
The sheet metal base of the   ireplace must be 
left in place and a minimum 1/2" cement board 
sheet placed under the entire length and width 
of the appliance.

WARNING: Failure to position the parts 
in accordance with the diagrams in this 
manual or failure to use only parts specii-
cally approved with this appliance may 
result in property damage or personal 
injury.

Содержание liberty LRI3E

Страница 1: ...ectrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach you gas supplier call the ire department Installation and service must be performed by a qualiied installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow sa...

Страница 2: ...th safety and eficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace This product may be installed in an aftermarket perma nentlylocated manufacturehome USAonly ormobile home where not prohibited by...

Страница 3: ...3 HRI3E Parts list 44 HRI3E Main assembly 45 Accessories 46 Warranty Warranty 48 Dimensions Unit dimensions with vignette faceplate 4 Unit dimensions with vignette faceplate small backing plate 4 Unit dimensions with 4 sided vignette faceplate backing plate 5 Installation Copy of Safety Label HRI3E 6 Copy of Safety Label LRI3E 7 MA Code CO Detector 8 Important Message 9 Before You Start 9 Importan...

Страница 4: ...ALL BACKING PLATE 10 3 8 29 1 16 22 3 4 22 1 2 26 19 28 14 21 5 16 1 13 16 711mm 540mm 355mm 738mm 660mm 572mm 576mm 45mm 262mm 482mm 738mm 29 1 16 794mm 31 1 4 23 3 8 593 mm 14 1 4 36 2mm 22 11 16 576mm 21 5 16 540mm 711mm 28 1 7 8 47mm Not Shown Regular backing plate 35 3 4 W x 25 5 8 H Oversize backing plate 38 3 16 W x 29 5 8 H ...

Страница 5: ...ect Vent Gas Insert 5 5 dimensions UNIT DIMENSIONS WITH 4 SIDED VIGNETTE FACEPLATE BACKING PLATE 28 5 8 726mm 29 1 4 743mm 35 3 4 908mm 28 711mm 21 5 16 540mm 1 15 16 48mm 10 3 8 262mm 3 76mm 19 482mm 14 355mm 3 76mm ...

Страница 6: ...pliance is not convertible for use with other gases unless a certified kit is used This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes See owner s manual for details WARNING This fireplace has been converted for use with a gas fireplace insert only a...

Страница 7: ...ppliance is not convertible for use with other gases unless a certified kit is used This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes See owner s manual for details WARNING This fireplace has been converted for use with a gas fireplace insert only ...

Страница 8: ...tly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspecti...

Страница 9: ...DLERS YOUNG CHILDREN ANDOTHERATRISKINDIVIDUALSOUT OF THE ROOM AND AWAY FROM HOT SURFACES A BARRIER DESIGNED TO REDUCE THE RISK OF BURNS FROM THE HOT VIEWING GLASS IS PROVIDED WITH THIS APPLIANCE AND SHALL BE INSTALLED FOR THE PROTECTION OF CHILDREN AND OTHER AT RISK INDIVIDUALS IFTHE BARRIER BECOMES DAMAGED THE BARRIER SHALL BE REPLACED WITHTHEMANUFACTURER SBARRIER FOR THIS APPLIANCE ANY SAFETY SC...

Страница 10: ...s long as these items are saved and are reinstalled in the event that the Insert is removed The ireplace lue damper can be fully blocked open or removed for installation of the gas ireplace insert Smokeshelves shieldsandbaflesmayberemoved if attached by mechanical fasteners If any part is removed it must not weaken the structural integrity of the factory built ireplace The ireplace and ireplace ch...

Страница 11: ...s and fasten to the front plate Refer to section Flue Liner Installation 6 Slide the unit fully into the ireplace Level if necessary 7 Hook up 120 volt AC power cord into a suitable receptacle Optional Install 4 batteries in the battery pack Batteries only serve as back up if power is lost within the home 8 Test gas pressure Refer to section Gas Pipe Pressure Testing Check aeration system Refertos...

Страница 12: ...rom Base of Unit D Min Hearth Depth 12 305mm Not required if unit raised 3 1 2 off loor E Min Hearth Length 36 914mm G Max Mantle Depth 0 12 305 mm 47 1193mm from bottom of unit K Min Alcove Width 54 1372 mm L Max Alcove Depth 36 914 mm M Mantel Delector 3 1 2 89mm NOTE 36 914 mm wide x 12 305mm deep non combustible hearth is required in front of the appliance unless the unit is raised 3 1 2 89 mm...

Страница 13: ...l Connections Minimum 8 ft 2 44m Maximum 35 ft 10 67m Exhaust Flue 2 Liner 3 Liner 3 Collar Flashing FPI Co linear DV Vertical Termination Cap Full continuous length unit to cap is required for both intake exhaust The LRI3E HRI3E are also approved for use with a 2 liner for air intake and a 3 liner for exhaust This would be suitable for a Class A wood burning chimney with a minimum 6 round lue The...

Страница 14: ... feet the restrictor is not required 1 Remove lue connecter plate by sliding out toward the back of the unit see previous page 2 Removeleftlueconnectorplateguidebyremoving2screwsasshownbelow tooltip Flue connector plate guide tooltip Restrictor plate 3 Flip the lue connector plate gasket to the right out of the way to allow ease of installation of the vent restrictor 4 Install vent restrictor with...

Страница 15: ...he Flue Connector Plate is fully forward and the Rear Tabs are fully engaged 6 Remove the Flue Connector Tool and store for future use 2 Attach the Flue Liners onto the Flue Connector Plate using non RTV type sealant then fasten with 3 screws See the section in this manual on Venting installation 3 Position the unit in front of the ireplace opening start the Flue Connec tor Plate into the Flue Con...

Страница 16: ...Fuel Type Min Air Setting LRI3E NG 1 8 3mm LRI3E LP 1 4 6mm HRI3E NG 1 8 3mm HRI3E LP 5 16 8mm NOTE In higher elevations air shutter settings may have to be opened more to compensate The minimum air settings noted for the HRI3 are good for both media and driftwood log set AIR SHUTTER ADJUSTMENT CAUTION Carbon will be produced if air shutter is closed too much Note any damage due to carboning resul...

Страница 17: ...cipalities have additional local codes it is always best to consult with your local authorities and the CAN CGA B149 installation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or lex connectors use only approved ittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper line...

Страница 18: ...n Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges GND GND GND BLACK RED RED BLACK BLACK BLACK BLACK YELLOW RED GREEN GREEN GREEN BATTERY BOX RECEIVER FAN CONTROL MODULE VALVE FAN GOLD TC SW 0 I ON OFF THERMOCOUPLE SENSOR 885 If any of the original wire as supplied with the appliance must be replaced it must be replaced with type CPE wire or its equivalent ...

Страница 19: ... s instructions and all applicable codes and requirements of the authority having jurisdiction If these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The quali fied service agency is responsible for the proper installation of this kit The installation is not proper and complete until the ope...

Страница 20: ...trol Installer Notice These instructions must be left with the appliance 8 Remove burner orifice with a 1 2 wrench Use another wrench to hold onto the elbow behind the orifice Recycle orifice 9 Reinstall new burner orifice LPG stamped 55 and tighten 7 Replace the NG pilot orifice with the supplied LP pilot orifice using the supplied 5 32 allen key Burner orifice 6 From inside the firebox remove pil...

Страница 21: ...anic Stones DO NOT cover burner ports or pilot light that leads to pilot lame BURNER PACKAGES Unit Glass Crystals Fire Beads Stones Spa Ceramic Volcanic Stones Pebbles Driftwood Logs HRI3E 4 lbs 4 lbs 4 lbs Glass burner 1 package 70 Spa Stones 4 lbs Beads burner 1 package 70 Spa Stones 4 lbs Glass burner 26 Volcanic Stones 4 lbs Beads burner 26 Volcanic Stones 4 lbs Glass burner 1 bags Pebbles NOT...

Страница 22: ...rmance which is not covered under warranty For Touch Ups Dark Brown paint is included 1 Rear Centre Log 2 Left Angled Log 3 Right Angled Y Shaped Log 4 a Left Front Log Piece 4b Right Front Log Piece Embers 1 2 3 4a 4b 1 3 2 4a 4 1 2 4b 3 Install Log 1 at the back of the firebox resting on the firebox and the brackets installed in the previous step 4 Install Log 4a seat it on the glass crystals bu...

Страница 23: ...shown Note do not cover burner ports with embers This will cause soothing on the logs 8 Test fire to ensure proper light off make sure flame flows smoothly from one end of the burner to the other If there is any flame hesitation check that area for any blockage of the burner ports Ember install Final install ...

Страница 24: ...not covered under warranty For Touch Ups Dark Brown paint is included 1 Rear Centre Log 2 Left Angled Log 3 Right Angled Log 4 Left Front Log Piece 5 Right Front Log Piece 6 Centre Log 7 Centre Right Cross Log 1 2 3 4 7 6 5 1 4 5 2 3 Log 3 install 2 InstallLog2 Log2willrestdiagonallyintheindentontheleftsideofLog 1 the bottom end with rest in the indent of the burner as shown below 3 Install Log 3 ...

Страница 25: ... diagonal one end will rest in an indent in the burner and the other end will rest at the Y on Log 3 8 Test fire to ensure proper light off make sure flame flows smoothly from one end of the burner to the other If there is any flame hesitation check that area for any blockage of the burner ports Final install Log 6 install Log 7 install ...

Страница 26: ...inst back wall of irebox the side panels once installed will secure the back panel in position Install back brick panel Install left brick panel Install right brick panel Final install 3 Loosen bracket screw in irebox in location shown below slide left brick panel into position until it contacts the back panel Slide the panel bracket on from the front of the unit and tighten the bracket screw 4 Lo...

Страница 27: ...cloth Use an ammonia based cleaner ie glass cleaner to remove any ingerprints before applying heat to the unit Failure to do this will result in burn stains on panels which you will be unable to remove Not protected by product warranty 1 Carefully unpack painted black or enamel panels 2 Install back painted enamel panel place against back wall of irebox the side panels once installed will secure t...

Страница 28: ... of the glass panels should be done by a licensed or qualiied service person Door Tool Door Latch tooltip 4 Release the side door latch until it reaches its resting point 5 Support the top of door as it will fall forward after the 2nd door latch is re leased The bottom of the door will be supported in the lower frame Note Gently ease the glass back Do not put any force on the glass assembly as thi...

Страница 29: ...ack faceplate and secure with 4 screws as shown 2 Install the outer front faceplate by hooking the flange over the hanger located on the back faceplate installed in the previous step as shown Final Install Back Faceplate Install Front Faceplate Install VIGNETTE FACEPLATE WITH SAFETY SCREEN INSTALLATION ...

Страница 30: ... 1 Remove 5 screws from the backside of the Vignette frame cover and keep them aside 3 at bottom and 2 at top 3 Place the Inlay on the Front Trim Assembly 4 Center the inlay inside the Front Trim Assembly 2 Take the mesh screen out of the Vignette front frame as shown below Vignette Frame Vignette Frame Cover ...

Страница 31: ...1 31 installation 5 With the Inlay in position place the mesh screen over the inlay NOTE The flush side of the mesh screen should face the inlay 7 Install the Vignette frame with Inlay onto the 2 hooks provided on the unit 6 Reverse step1 ...

Страница 32: ...eplate from the front with 6 screws 4 along the top and 1 on each side 4 Reinstall the back faceplate with backing plate reverse Step 2 5 Reinstall the Vignette faceplate and safety screen to complete tooltip 2 Remove the back faceplate by removing the 4 screws as shown Note the two top and two bottom screws can be loosened slide the back faceplate up on out to remove Remove Front Faceplate Backin...

Страница 33: ... to the hearth to measure the height required 3 Ensuring back faceplate is in place line up the hearth trim with base of the unit and secure it with 2 screws as shown below 2 Reattach the top piece of the hearth trim to the cut bottom piece by itting in place and secure with supplied clips one on each side 152 mm 51 mm tooltip tooltip 919 710 A mantel delector may be installed to reduce the minimu...

Страница 34: ... operating this appliance 2 Check to see that all wiring is correct and en closed to prevent possible shock 3 Check to ensure there are no gas leaks 4 Makesuretheglassdoorisinplace Neveroper ate the appliance with the door glass removed 5 Verifythatallventingandthecapisunobstructed 6 Verify log glass crystal placement If the pilot cannot be seen when lighting the unit the logs crystals or the embe...

Страница 35: ...ructions Important The remote control Receiver for this appliance comes pre coded for your convenience and does not require to be recoded after changing batteries in the hand held As long as there is 120 volt power to the appliance and a 9 volt battery in the remote handset this will operate as normal If the remote for some reason ever required to be re coded as a result of losing its learning cod...

Страница 36: ...n accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 or Natural Gas and Propane Installation Codes CSA B149 1 CAUTION Hot while in operation Do not touch Severe Burns may result Due to high surface temperatures keep children clothing and furniture gasoline and other liquids having lammable vapors away Keep burner and control compartment clean See insta...

Страница 37: ...applianceandtoreplace anypartofthecontrolsystemandanygascontrol which has been under water 8 Periodicallycheckthepilotlames Correctlame pattern has two strong blue lames 1 lowing around the lame sensor and 1 lowing across the burner it does not have to be touching the burner 9 Proper reassembly and resealing of the vent air intake system must be completed when servicingtheappliance Seelue ventinst...

Страница 38: ...s valve and allow the unit to cool before opening door to carefully remove the logs The pilot light generates enough heat to burn someone If for any reason a log should need replacement you must use the proper replacement log The position of these logs must be as shown in the diagram under Log Installation NOTE Improper positioning of logs may create carbonbuild upandwillaltertheunit sperformance ...

Страница 39: ...you begin Shut off the gas supply to the unit Disconnect all electrical supply to the unit Always let the appliance cool to room temperature before servicing Note To access the side and rear access panels both the gas and vent ing will need to be disconnected see vent lue installation in this manual for proper removal There is no access to the blower from the front of this appliance 1 Remove 5 scr...

Страница 40: ...l Panel Cover 3 Disconnect gas line from valve 4 Disconnect the lame electrode wire from the remote receiver box Slide remote receiver box out to access the wire tooltip Remove Loosen 5 Disconnect the wiring harness from the front of the valve use a lat head screw driver to pry the tab loose to remove 6 Remove the burner LRI3E HRI3E burner cover burner LRI3E Remove the burner by removing 2 screws ...

Страница 41: ...n below tooltip 10 Lift out panel part of valve assembly with valve and pilot assembly Diagram 7 Diagram 8 Diagram 9 11 Replace with new valve assembly ensuring to use a new gasket before securing new valve access plate to unit 12 Reassemble unit by reversing Steps 8 1 13 Reconnect the gas and electrical supply to the unit Once the unit has been reired use a soapy water mixture to check all itting...

Страница 42: ...riice 55 LP Not Shown Part Description N S 904 529 Allen Key 5 32 Long N S 905 003 Minimum Rate Screw 0 95mm LP N S 911 198 Thermocouple Interrupter N S 932 024 Tubing SS Flexible 3 8 x 24 inch N S 904 599 Fitting Elbow 90 Degree N S 904 629 Fitting Elbow 90 Degree Forged N S 911 195 Plug Pipe 3 8 NPT 1005 14 Each N S 904 658 Inlet Flex Line Gas SS Steel 24 inch N S 716 046 Valve Assembly Gasket N...

Страница 43: ...LRI3E HRI3E Direct Vent Gas Insert 43 43 parts list LRI3E MAIN ASSEMBLY 10 12 18 17 19 9 22 20 14 25 15 21 11 8 16 24 13 3 4 4a 4b 5 6 7 7 2 1 ...

Страница 44: ...9 Allen Key 5 32 Long N S 905 003 Minimum Rate Screw 0 95mm LP N S 911 198 Thermocouple Interrupter N S 932 024 Tubing SS Flexible 3 8 x 24 inch N S 904 599 Fitting Elbow 90 Degree N S 904 629 Fitting Elbow 90 Degree Forged N S 911 195 Plug Pipe 3 8 NPT 1005 14 Each N S 904 658 Inlet Flex Line Gas SS Steel 24 inch N S 716 046 Valve Assembly Gasket N S 936 221 Orange Gasket Side Firebox N S 911 196...

Страница 45: ...LRI3E HRI3E Direct Vent Gas Insert 45 45 maintenance 10 12 17 18 19 9 23 20 21 3 4 4a 4b 5 6 7 2 1 25 7 22 11 8 16 24 13 HRI3E MAIN ASSEMBLY ...

Страница 46: ...own 716 902 Brick Panel Standard Red 716 703 Brick Panel Standard Black 716 908 Inner Panel Black Enamel 716 911 Vignette Door Inlay Tuscan Sunset 716 912 Vignette Door Inlay Black Chrome 716 913 Vignette Door Inlay Metallic Black 716 914 Vignette Craftsman Inlay Tuscan Sunset 716 915 Vignette Craftsman Inlay Black Chrome 716 916 Vignette Craftsman Inlay Metallic Black 716 925 Backing Plate Vignet...

Страница 47: ...LRI3E HRI3E Direct Vent Gas Insert 47 47 notes ...

Страница 48: ...wers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless her...

Страница 49: ...wndrafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the...

Страница 50: ...al provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief description of the problem a...

Страница 51: ...in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases ma...

Страница 52: ......

Страница 53: ...LRI3E HRI3E Direct Vent Gas Insert 53 53 notes ...

Страница 54: ...54 LRI3E HRI3E Direct Vent Gas Insert 54 notes ...

Страница 55: ......

Страница 56: ... information Dealer Name Address ______________________________________________ ___________________________________________________________________ Installer ___________________________________________________________ Phone ___________________________________________________________ Date Installed ______________________________________________________ Serial No ____________________________________...

Отзывы: