40
|
LRI3E / HRI3E Direct Vent Gas Insert
|
40
maintenance
VALVE REPLACEMENT
Before you begin:
* Shut off the gas supply to the unit.
Disconnect all electrical supply to the unit.
Always let the appliance cool to room temperature before servic-
ing.
Note:
To access the left control panel cover, the venting will need to be
disconnected (see vent/lue installation in this manual) for proper removal.
1. Remove the Faceplate, glass door and inner panels - see instructions in
this manual.
2. Remove the Left Control Panel Cover.
3. Disconnect gas line from valve.
4. Disconnect the lame electrode wire from the remote receiver box. Slide
remote receiver box out to access the wire.
tooltip
Remove
Loosen
5. Disconnect the wiring harness from the front of the valve—use a lat head
screw driver to pry the tab loose to remove.
6. Remove the burner.
LRI3E
HRI3E
burner cover
burner
LRI3E- Remove the burner by removing 2 screws in locations shown below.
HRI3E - Remove the burner by removing 5 screws in locations shown below
to remove burner cover and 2 screws to remove burner (shown below).
tooltip
7. Remove the burner support by removing 3 screws as shown below.
Diagram 1
Diagram 4
Diagram 5
Diagram 6
Diagram 2
Diagram 3