LRI3E / HRI3E Direct Vent Gas Insert
|
19
|
19
installation
This conversion should be done before the unit is initially installed:
If installed already, the draft hood assembly will need to be removed
so appliance may be slid out from the fi replace opening for ease of
conversion. See manual for details
Before you begin:
Shut off the gas supply to the unit.
Disconnect all electrical supply to the unit.
Always let the appliance cool to room temperature before servicing.
1. Remove faceplate, glass door , inner panels, glass crystals, media, logs
(if already installed)—see instructions in the manual.
2. Slide unit out and remove 3 front screws and loosen 2 back screws to
remove the left side control cover.
3. Remove minimum rate screw with 5/32" allen key (provided) and replace with
minimum rate screw supplied with LP conversion kit. Do not overtighten—this
screw can be easily damaged.
3. Remove conversion plug (located between the control knobs) with a long
fl at head screwdriver—access the plug from front of unit.
WARNING
This conversion kit shall be installed by a qualifi ed service agency in ac-
cordance with the manufacturer’s instructions and all applicable codes and
requirements of the authority having jurisdiction. If these instructions is not
followed exactly, a fi re, explosion or production of carbon monoxide may
result causing property damage, personal injury or loss of life. The quali-
fi ed service agency is responsible for the proper installation of this kit. The
installation is not proper and complete until the operation of the converted
appliance is checked as specifi ed in the manufacturer’s instructions sup-
plied with the kit.
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION!
Conversion plug
LRI3E
Conversion Kit includes:
1
904-575
Orifi ce #55
1
910-101
Pilot Orifi ce #35
1
918-590
Decal - Conversion to LP
1
905-003
Minimum rate screw
1
904-529
5/32" long Allen Key
1
908-528
Label Propane Red
4. Remove the blue plastic end on the conversion plug and fl ip 180
º
reinstall
blue plastic end in LP position (slide blue plastic onto plug until a click is felt)
and reinstall on to valve. Use care to hand tighten only to avoid damaging
the conversion plug.
5. LRI3E- Remove the burner by removing 2 screws in locations shown below.
HRI3E- See next page.
Side control cover
Minimum rate
screw
Conversion plug
CONVERSION FROM NG TO LP
LRI3E /HRI3E using GV60 Maxitrol Gas Valve
Содержание liberty LRI3E
Страница 47: ...LRI3E HRI3E Direct Vent Gas Insert 47 47 notes ...
Страница 52: ......
Страница 53: ...LRI3E HRI3E Direct Vent Gas Insert 53 53 notes ...
Страница 54: ...54 LRI3E HRI3E Direct Vent Gas Insert 54 notes ...
Страница 55: ......