Regency Horizon HZ30E-10 Gas Fireplace
|
32
installation
Vertical Venting with Three (3. 90
o
Elbows
V
H1
H
V1
V
V1
H1
H
Vertical Venting with Three (3. 90
o
Elbows
Option H
V
H + H1 V + V1
A)
1' Max. 1' Min. 3' Max. 3' Min.
B)
2' Max. 2' Min. 4' Max. 5' Min.
C)
3' Max. 3' Min.' 5' Max. 7' Min.
D)
4' Max. 4' Min. 6' Max. 9' Min.
E)
5' Max. 5' Min. 7' Max. 11' Min.
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
With these options, max. total
pipe length is 28 feet with min.
of 11 feet total vertical and
max. 7 feet total horizontal.
Please note min. 1 foot
between 90
o
elbows is
required.
Option V
H + H1 V + V1
A)
2' Min. 3' Max. 4' Min.
B)
3' Min. 4' Max. 6' Min.
C) 4' Min. 5' Max. 7' Min.
D) 5' Min. 6' Max. 8' Min.
E)
6' Min. 7' Max. 9' Min.
F)
7' Min. 8' Max. 10' Min.
With these options, max. total
pipe length is 28 feet with min.
of 10 feet total vertical and
max. 8 feet total horizontal.
Please note min. 1 foot
between 90
o
elbows is
required.
Restrictor Position - Set 0 (factory setting)
Restrictor Position - Set 0 (factory setting)