38
|
Regency Horizon HZ30E-10 Gas Fireplace
|
38
installation
OPTIONAL FAN INSTALLATION
120 Volt AC power is needed for the fan. The fan can be hard wired if desired.
The outlet should be installed in the receptacle box on the right hand side by a
qualified electrician. The neutral (wider) slot of the polarized outlet should be at
the top.
Unit must be grounded at all times. Do not cut the ground terminal off
under any circumstances.
Follow these instructions before the
initial installation
into the framing. If
installing the optional fan into an existing installation see the instructions on the
following pages.
1. Remove the 2 screws and remove the front access panel.
2. Slide the fan through the front access panel into the lower right corner at the
base of the unit. Secure the fan to the base with 2 screws
3. Attach the green ground wire to the ground lug – located in the lower left back
corner of the unit.
4. Slide the thermodisc/cover assembly on to the bracket clip on the bottom of
the unit. Ensure no wires will touch the hot surfaces.
The fan control module (supplied with the fan kit) secures to the floor of the
unit with a Velcro pad. The front of the fan control module should face to the
left directly in front of the fan. Plug the fan control module into the outlet in the
unit.
5. Plug in the fan power cord to the Fan Control Module into the outlet marked
“Fan”. Plug the FCM-COM wire from the remote control wiring harness into the
location on the Fan Control Module marked “COM”. Turn the switch on the
Fan Control Module to the ON position. ON is to the left. The “O” is the off
position
6. Reinstall the access panel removed in step 1.
Note:
The HZ30-10 does not have BTU turndown therefore this feature is
inactive on the GTMF remote.
TO REMOVE THE FAN
1)
Turn the power off.
2)
Reverse the above instructions
MAINTENANCE:
The sealed bearings are lubricated so there is no need to
lubricate them further. Extra lubricant will cause more lint to and dust to build
up causing the premature failure of the bearings.
Regular cleaning and vacuuming of the fan area will add to the life of the
motor
Screw Locations
IMPORTANT:
These fans collect a lot of dust from within your home.
Ensure you maintain these fan motors on a regular
basis by vacuuming the fan blades and the housing with
a soft brush nozzle.
Содержание Horizon HZ30E
Страница 58: ...58 Regency Horizon HZ30E 10 Gas Fireplace 58 parts list 1 2 3 4 11 10 5 8 ...
Страница 60: ...60 Regency Horizon HZ30E 10 Gas Fireplace 60 notes ...
Страница 61: ...Regency Horizon HZ30E 10 Gas Fireplace 61 61 notes ...
Страница 62: ...62 Regency Horizon HZ30E 10 Gas Fireplace 62 notes ...