Regency Horizon HZ30E-10 Gas Fireplace
|
27
|
27
installation
V1
H1
H
V
Horizontal Venting with Three (3. 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
Option
V
H
V + V1
H + H1
With these options,
maximum total pipe
length is 28 feet with
minimum of 12 feet
total vertical and
maximum 9 feet total
horizontal.
P l e a s e n o t e
minimum 1 foot
between 90
o
elbows
is required.
A)
2' Min. 1' Max.
3' Min.
4' Max.
B)
3' Min. 2' Max.
4' Min.
5' Max.
C)
4' Min. 3' Max.
6' Min.
6' Max.
D)
5' Min. 4' Max.
8' Min.
7' Max.
E)
6' Min. 5' Max.
10' Min.
8' Max.
F)
7' Min. 6' Max.
12' Min.
9' Max.
Restrictor Position - Set 0 (factory setting)