background image

3.OD.3A

ALL INSTRUCTIONS TO COMPLY WITH AS/NZS2918:2001

Due to continued product improvement, The Fireplace Ltd reserves the right to change product specifications without prior notification

instructiOns ArE fOr instAllAtiOn intO A cOmplEtE mAsOnry firEplAcE cOnstructiOn i.E: 

cAvity AnD chimnEy chAsE (nO cOmBustiBlEs)

Masonry Definition

:  - Solid Concrete

  

 

 

- Concrete/Masonry Block 

 

 

   - 

Brick

  

 

 

- Hebel Block/Panel

Consult The Fireplace Ltd or your local agent for any variation of the installation specified below

nOtE:

 If using timber framing, refer to 5.TW.1A for installation instructions. A Heat Shield must be used.

JETMASTER OUTDOOR WOOD FIRE  & ALFRESCO BBQ  

INSTALLATION INSTRUCTIONS TYPICAL IN-BUILT MASONRY BLOCK

9/2013

IMPORTANT: Read all instructions carefully before starting installation. Failure to follow these 

instructions may result in a fire hazard and will void the warranty.

Содержание JETMASTER 700 D

Страница 1: ...n Solid Concrete Concrete Masonry Block Brick Hebel Block Panel Consult The Fireplace Ltd or your local agent for any variation of the installation specified below NOTE If using timber framing refer to 5 TW 1A for installation instructions A Heat Shield must be used JETMASTER OUTDOOR WOOD FIRE ALFRESCO BBQ INSTALLATION INSTRUCTIONS TYPICAL IN BUILT MASONRY BLOCK 9 2013 IMPORTANT Read all instructi...

Страница 2: ...ntry between the inner flue pipe and flue pipe casing or the air circulation between the vent holes in the cavity 3 Refer to Table 2 Fig 3 for minimum hearth sizes Please note a hearth is not required when the floor surface below the fire is non combustible ie concrete pavers etc Table 2 MINIMUM CAVITY SIZE Refer to Table 2 for the minimum cavity dimensions and temporary lintel height measurements...

Страница 3: ...2 for temporary lintel height Jetmaster Flange Allow 5mm gap between plaster and flange to ensure stainless steel cover can be fitted to the box DO NOT PLASTER OVER THE FLANGE A minimum 75mm thick Floor protector is only required if finished surface is combustible e g timber decking Please note that these dimensions based on Masonry margins are the absolute minimum sizes widths A B maybe increased...

Страница 4: ... fitted over the flue pipe 6 Before fitting casing cover place the spider in opposition with the spider post facing down between the flue pipe and flue pipe casing Secure spider in position Place the casing cover over the flue pipe press down firmly onto the spider Check airway around the casing cover is clear then secure in position using three stainless steel rivets 7 Fit cowl to top of flue DO ...

Отзывы: