Regency GF1500LST Gas Fireplace
7
installation
This includes:
1. Clocking the appliance to ensure the correct
firing rate (rate noted on label) after burning
appliance for 15 minutes.
2. If required, adjusting the primary air to ensure
that the flame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
LOCATING YOUR
GAS FIREPLACE
1. When selecting a location for your fireplace,
ensure that the clearances are met.
2. The appliance must be installed on a flat solid
continuous surface, for example a wood,
metal or concrete floor. In a raised application
e.g. on wall, the appliance must be installed
on a sturdy metal, wood or concrete surface
extending the full width and depth of the
appliance.
INSTALLATION CHECKLIST
1. Locate appliance
a) Room location (Refer to "Locating Your
Gas fireplace" section)
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Mantle Clearances (Refer to "Mantel
Clearances" section)
d) Framing & Finishing Requirements
(Refer to "Framing & Finishing" section)
e) Flueing Requirements (Refer to "Flue"
section)
2. Assemble the standoffs and nailing strips
(Refer to "Unit Assembly Prior to Installation).
3. Slide unit into place.
4. Install flue (Refer to "Flue Arrangement"
sections).
5. Make gas connections (Refer to "Gas Line
Installation section).
6. Pair up Remote Control (Refer to "Pairing up
Remote Handset" section)
7. Test the pilot (Refer to "Pilot Adjustment"
section).
8. Test Gas Pressure (Refer to "Gas Pipe Pres-
sure Testing" section).
9. Install standard and optional features. Refer
to the following sections:
a)
Log Install
b)
Faceplate / Door Frame Overlay
c)
Remote Control
10. Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and
operation fully explained to
customer
.
3. The GF1500LST Direct Vent Gas Fireplace
can be installed as follows:
Glass
914mm
914mm
114mm
Glass
914mm
914mm
914mm walkway
Glass
Glass
Warmer
side
Warmer
side
4. The GF1500LST Direct Vent Gas Fireplace
is approved for alcove installations, see
"Clearances" section for details.
5. We recommend that you plan your installation
on paper using exact measurements for
clearances and floor protection before
actually installing this appliance. Have an
authorized inspector, dealer, or installer
review your plans before installation
.
Note: For flue terminations refer to "Exterior
Flue Termination Locations" section.
NOTE: DUE TO NATURE AND DE-
SIGN OF THE GF1500LST DOUBLE
SIDED UNIT, SIDE A PROJECTS
MORE HEAT THAN SIDE B ON THE
UNIT. PLEASE NOTE THIS BEFORE
COMMENCING THE INSTALLATION
PROCESS.
Содержание GF1500LST-LP
Страница 51: ...Regency GF1500LST Gas Fireplace 51 PARTS LIST parts list MAIN ASSEMBLY SIDE A SIDE B ...
Страница 53: ...Regency GF1500LST Gas Fireplace 53 NOTES notes ...
Страница 60: ......
Страница 61: ...Regency GF1500LST Gas Fireplace 61 NOTES notes ...
Страница 62: ...62 Regency GF1500LST Gas Fireplace NOTES notes ...
Страница 63: ......