Regency GF1500LST Gas Fireplace
27
installation
Note: If an offset is necessary in the roof space
to avoid obstructions, it is important to
support the flue pipe every 0.9 meter,
to avoid excessive stress on the elbows,
and possible separation. Metal Wall
straps can be used (Diagram 2). Do not
combine flueing components from other
manufacturers.
Galvanized pipe is desirable above the roofline
due to its higher corrosion resistance. Continue
to add pipe sections through the flashing until the
height of the flue cap meets the minimum height
requirements specified in local codes. Note that
for steep roof pitches, the vertical height must be
increased.
Note: For best results and optimum
performance with each approved
flueing system, “Mill-Pac” sealant to
every inner pipe connection. Failure
to do so may result in drafting or
performance issues not covered
under warranty.
UNIT INSTALLATION WITH
VERTICAL TERMINATION
(Rigid Systems)
Note: A clearance of 51mm must be
maintained. .
1. Do not pack air spaces with insulation. Check
"Flueing Arrangement - Vertical Termination"
section for the maximum vertical rise of the
flueing system and the maximum horizontal
offset limitations.
2. Set the gas appliance in
its desired location. Drop a
plumb bob down from the
ceiling to the position of the
appliance flue exit, and mark
the location where the flue
will penetrate the ceiling.
Drill a small hole at his point.
Next, drop a plumb bob from
the roof to the hole previ-
ously drilled in the ceiling,
and mark the spot where the
flue will penetrate the roof.
Determine if ceiling joists,
roof rafters or other fram-
ing will obstruct the flueing
system. You may wish to
relocate the appliance or to
offset, as shown in Diagram 2
to avoid cutting load bearing members.
3. Cut a hole large enough to allow for proper
clearances .
4. Assemble the desired lengths of pipe and
elbows. Ensure that all pipes and elbow con-
nections are in the fully twist-locked position
and sealed.
5.
Cut a hole in the roof centered on the small
drilled hole placed in the roof in Step 2.
The hole
should be of sufficient size to meet
the minimum requirements for clearance to
combustibles of 51mm.
6. Continue to assemble pipe lengths.
A poor draft, or down drafting can result from
high wind conditions near big trees or adjoining
roof lines, in these cases, increasing the flue
height may solve the problem. Maximum
height is 6.7 meters.
7. Penetrate roof and secure flashing (supplied
by installer)
8. Install the vertical termination cap .
Note: Any closets or storage spaces, which the
flue passes through must be enclosed.
Diagram 2
"THIS UNIT MUST ALWAYS
TERMINATE / FLUE
DIRECTLY TO THE OUTDOORS."
Diagram 1
Metal Wall
Strap
Diagram 5
Flue Height
(Minimum600mm)
As Per AS/NZS 5601-2013
Содержание GF1500LST-LP
Страница 51: ...Regency GF1500LST Gas Fireplace 51 PARTS LIST parts list MAIN ASSEMBLY SIDE A SIDE B ...
Страница 53: ...Regency GF1500LST Gas Fireplace 53 NOTES notes ...
Страница 60: ......
Страница 61: ...Regency GF1500LST Gas Fireplace 61 NOTES notes ...
Страница 62: ...62 Regency GF1500LST Gas Fireplace NOTES notes ...
Страница 63: ......