46
Regency GF1500LST Gas Fireplace
maintenance
TROUBLESHOOTING
ALL WORK MUST BE CARRIED OUT BY A LICENSED, QUALIFIED TECHNICIAN
It is critical that this appliance is earthed and that the Active and Neutral are not crossed.
SYMPTOM
CAUSE
SOLUTION
Unit does not operate
(no ignition, no fans)
No power supply (240V) to unit or control box Check 240V power supply
Unit will not operate using remote control, but
OK using manual control
Remote control not tuned into unit
Tune remote control into unit
Unit goes through ignition cycle but pilot light
does not ignite
No gas to unit or fitting line has not been purged Check gas supply or purge fitting line
Pilot light ignites but main burner does not
ignite, igniter continues to spark for 30 sec-
ondes then goes to lockout
Crossed polarity or faulty sensor lead/ circuit
Faulty extension lead or power board
Check polarity at power point connection into
heater and control box
Remove or replace extension lead or power
board
Unit ignites, main burner becomes unstable,
flame lifts off burner, unit goes into lockout
Flue blocked,
Incorrect flue installation or
Flue joints not sealed
Incorrect burner pressure settings
Burner aeration not correctly adjusted
Log set incorrectly installed
Clear blocked flue,
Install flue correctly
Seal all flue joints
Adjust burner pressure to correct setting
Adjust burner aeration
Install log set as per Owners' Manual
Fan operates but no ignition sequence
(no spark)
Unit ignition pack gone into lockout
Reset ignition pack by depressing black reset
button while unit controls are in the "ON
"
position (fan running)
Содержание GF1500LST-LP
Страница 51: ...Regency GF1500LST Gas Fireplace 51 PARTS LIST parts list MAIN ASSEMBLY SIDE A SIDE B ...
Страница 53: ...Regency GF1500LST Gas Fireplace 53 NOTES notes ...
Страница 60: ......
Страница 61: ...Regency GF1500LST Gas Fireplace 61 NOTES notes ...
Страница 62: ...62 Regency GF1500LST Gas Fireplace NOTES notes ...
Страница 63: ......