City Series CB60E-1 | 39
installation
Clearances (3-sided)
The clearances listed below are minimum distances unless otherwise stated.
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that
this fireplace and vent system be installed only in accordance with these instructions.
Flue Clearances to Combustibles
Horizontal - Top
3"
Horizontal - Side
2"
Horizontal - Bottom
2"
Vertical
2"
Passing through wall/
floor/ceiling - when
firestop is used.
1-1/2"
Note: This appliance uses 5" x 8" venting.
E
F
B
Alcove
Clearance
Dimension
Measured From:
A1: Mantel Height (min.)
**
Top of Fireplace Opening
A: From Floor (min.)
10-1/4" (260mm)
Bottom of Fireplace Opening
B: Sidewall (on one side) min.
5 7/8" (149mm)
Side of Fireplace Opening
C: Enclosure Width (min.)
71-1/4" (1810mm)
Minimum inside dimensions
D: Mantel Depth (max.)
**
E: Alcove Width
119-1/2" (3035mm)
Sidewall to Sidewall (Minimum)
F: Alcove Depth
35" (889mm)
Front to Unit (Maximum)
G: Convection Air Outlet Opening Offset
(min.)
2" (50mm)
Max. offset from top of chase enclosure
H: Convection Air Outlet
180 square inches
I Enclosure Depth (min.)
20-5/16" (516mm)
Minimum inside dimensions
J: Opening Height
18" (457mm)
Bottom/Top of Fireplace Opening
K: To Ceiling (min.) all 3 sides
1-3/4"
To Top of Ceiling
L: Chase Enclosure (min.)
81-1/4" (2064mm)
From base of unit/floor to top of enclosure
M:Clearance to Sprinkler Head (min.)
36" (914mm)
Perpendicular from chase grill
Hearth
0"
No hearth required
** See mantel clearances chart in the manual.
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may
NOT
be
recessed into combustible construction.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are
not adhered to. It is of greatest importance that this fireplace
and vent system be installed only in accordance with these
instructions.
The
HeatWave
Duct Kit has
different clearance and framing re
-
quirements, check the
HeatWave
manual for details.
L
Chase grill
Sprinkler
Side view
M
Содержание City 686-927
Страница 55: ...City Series CB60E 1 55 installation 2 x 4 shown Max 2 x 6 Typical Installations Flush Install Recessed Install ...
Страница 115: ...City Series CB60E 1 115 notes ...
Страница 120: ...120 City Series CB60E 1 warranty ...
Страница 121: ...City Series CB60E 1 121 notes ...
Страница 122: ...122 City Series CB60E 1 notes ...
Страница 123: ......