52 | City Series CB60E-1
installation
Chase Vent Installation (White Front)
920-180
10.31.19
1
CITY SERIES
CB60E CHASE VENT INSTALLATION (WHITE FRONT)
Max 2”
Ceiling
Ceiling
Top of chase enclosure
Max 2”
Stud
Stud
Stud
Stud
60” Chase Vent
60” Chase
Screw to studs here
Vent
Finishing material
Finishing material
Opening for vent
3”-3.5”
Min 60.25”
Framed Opening must be between 3” and 3.5” tall, and at least 60.25” wide to accomodate the Chase vent.
The top of the chase vent opening must be 2”
Chase Vent is installed after finishing material.
or less from the top of the chase enclosure.