106 | City Series CB60E-1
maintenance
Aeration Adjustment
The burner aeration is factory set but may need adjusting due to either the
local gas supply or altitude. Open the air shutter for a blue flame or close
for a more yellow flame.
Note: If the firebox glass, logs, inner panels, etc. are already installed, the
aeration can be adjusted from outside the firebox.
1. Remove the centre access panel on the outer trim, if finishing material is
already installed, remove the glass safety barrier and center outer panel-
-see instructions in this manual.
Remove
2. Attach the handle to the aeration lever through the access opening--handle
will slide into position on the lever.
3. Adjust aeration accordingly.
Pushing lever in -- opens the air shutter.
Pulling the lever outward -- closes the air shutter.
Minimum Air Shutter Opening
NG 3/16"
NG with Logs
3/16"
NG with Stones
3/16"
LP
3/8"
LP with Logs
3/8"
LP with Stones
3/8"
Note: Any damage due to carboning resulting from improperly setting the
aeration controls is NOT covered under warranty.
4. Remove the handle by lifting up and out--replace the access door and
tighten the 2 screws. Hang the handle back onto the magnet.
5. Reverse to Step 1.
aeration
handle
NOTE: The aeration handle is located near the right hand side of the gas
valve access door -- attached by a magnet.
Содержание City 686-927
Страница 55: ...City Series CB60E 1 55 installation 2 x 4 shown Max 2 x 6 Typical Installations Flush Install Recessed Install ...
Страница 115: ...City Series CB60E 1 115 notes ...
Страница 120: ...120 City Series CB60E 1 warranty ...
Страница 121: ...City Series CB60E 1 121 notes ...
Страница 122: ...122 City Series CB60E 1 notes ...
Страница 123: ......