background image

1

 

 

 
 

 
 
 

 
 
 

 
 

 
 

COLLECTION RD 750,1000  

INSTRUCTION FOR INSTALLATION AND USE 

 

 

Содержание RD 750

Страница 1: ...1 COLLECTION RD 750 1000 INSTRUCTION FOR INSTALLATION AND USE...

Страница 2: ...S TYPE RD FROM FLAMMABLE MATERIALS LOCATION OF THE STOVE SMOKE PIPES 5 2 4 LOCATION THE FIREPLACE STOVE TYPE SERIES RD ON THE FLOOR 5 2 5 REQUIREMENTS FOR PASSING COMBUSTION AIS 5 2 6 INSTALLATION THE...

Страница 3: ...screw cover back with screw 1 and 2 Pic 2 For security reasons the door is locked from both left and right site Before installation of the stove please check lifting door lifting up down and opening s...

Страница 4: ...paint will harden and that give off smoke and a smell which starts after the fire has burned for about 10 minutes and lasts for about 15 minutes See to it that there is ample ventilation in the room...

Страница 5: ...series RD may not be from combustible materials respectively should be used for good thermal insulation Combustion pipe must be fitted to the fireplace chimney s mouthpiece furnace type series RD so t...

Страница 6: ...CM AIR INLET OPEN ALSO FOR EXTERNAL AIR INLET IS LOCATED AT THE BACK SIDE DOWN OF THE FIREPLACE STOVE SEE PIC 6 Setting up the high of fireplace insert can be in two ways 1 to do a special higher flo...

Страница 7: ...t register We recommend that you use the design grill M design which have many advantages Pic 7 8 NOTE The circulation of hot air is required to be in the room because of the reason to do not produce...

Страница 8: ...meter 200 mm Some chimneys may require different standard diameters In this case refer to the table for the height of the chimney and by reducing the possibility of reduction Chimney fireplace insert...

Страница 9: ...gal requirement but it also makes sense for your own safety Refractory bricks babble may still work perfectly even if they are cracked However if there are missing pieces of bricks material bricks mus...

Страница 10: ...tove type series RD During operating the fireplace stove type series RD is forbidden give the hand into the flow of heated air because of the security reasons there is too high temperature Fire in the...

Страница 11: ...serial number see Pic 15 TYPE fireplace stove RD RD 750 RD 1000 Rated thermal power kW 14 7 15 7 Average efficiency 82 82 Heat flow into the space kW 14 7 15 7 Power range kW 4 2 15 5 2 16 Flue gas te...

Страница 12: ...885 705 1327 5 1362 5 453 4 2 6 0 933 508 562 1091 750 RD...

Страница 13: ...1135 705 1327 5 562 1220 63 1183 4 2 6 0 210 508 1362 5 1341 453 1000 RD...

Страница 14: ...uctions Assembly installation or repair by a third party including the buyer Heat cracks which normally occur in the mantel In cases where changes have been made to the appliance without our consent I...

Отзывы: