151
g) Servo setting with dual rate
By switching the dual rate switch (fig. 1, pos. 13), the aileron, rudder and elevator deflection functions are changed
according to the transmitter programming. These settings do not have any influence on the reaction speed.
The dual rate function may be set at once or separately for the aileron, rudder and elevator functions. The set values
may be chosen between 0 and 120 for normal flight and activated dual rate. The set value applies for both servo
rotational directions and cannot be adjusted separately for each rotational direction.
To choose this function, first switch on the transmitter. Press the "UP" and "DN" buttons at once four times Use the
"UP" and "DN" buttons to select the following servo functions.
dA0 = set value for normal flight aileron = CH1 + CH2
dA1 = set value for dual rate for aileron CH1 + CH2
dE0 = set value for normal flight elevator CH1 + CH2
dE1 = set value for dual rate elevator CH1 + CH2
dr0 = set value for normal flight rudder = CH4
dr1 = set value for dual rate rudder = CH4
With the buttons "INC" or "DEC", you can adjust the values between 0 and 120.
If you choose control layout modes 3 or 4 and want to control a model with a delta wing mixer, chose the
"VP" flight programme for V-tail models instead of the "DP" flight programme for models with delta wings.
In this case, the programme item dual rate sets dual rate for the rudder under "dA0" and "dA1" (CH1) and
the dual-rate for the aileron under "dr0" and "dr1" (CH2 + CH4).
Figure 35
Содержание 20 77 60
Страница 41: ...41 Bild 3 ...
Страница 126: ...126 Figure 3 ...