Offer the housing body up to the Pivot Ball and pass the cable(s) through the gland(s), ensuring unused glands are
closed off to prevent damp air ingress.
•
Attach the housing body to the Pivot Ball assembly and refit, using the 4 Allen bolts. Ensure the rubber O-ring seals are
still fitted on each bolt. Tighten the locking ring using the optional wrench bar (Fig 8).
•
Upon re-fitting the housing body to the bracket arm; position the housing and tighten the locking ring with the wrench
bar, and tightening one of the grub screws using the supplied Allen wrench (2.5mm) This fixes the ring in place and
ensures the housing remains firmly in position (Fig 9)
Grub screw for fixing Locking ring in place
Using the optional wrench bar to tighten the lock ring