Vega 2010-PW Installation Guide
Version 1.5 June 2019
26
©Redvision CCTV Ltd. 2018 Content subject to change without prior notification. All rights reserved.
5.41
Wiper control settings (SW3):
The wiper has 3 states: On/Off/Auto. On enables manual control via the RS-485 interface. Auto enables a built-in timer, so that
the wiper operates for one cycle at specific intervals. Timed options are: 5/10/15/30-minute intervals, and are selected by
SW3
switch block:
UP = OFF (0) DOWN = ON (1)
1
2
3
4
5
6
7
8
Off
On
Auto
(Reserved)
30m
15m
10m
5m
Switches 1 to 3: Only select one DIP switch at any time.
For example:
Manual, RS-485 control is DIP switch 2 = ON (all others off)
Auto/15m is DIP switch 3 = ON, switch 6 = ON (all others off)
When Switch 2 is set to ON, but no RS-485 control is used, alarm input 1 (pins 1&2 on JP6) can be used to manually activate the
wiper as a voltage-free closing contact.
The wiper will run for as long as the contact remains closed.
Note: The Auto-timer function requires one wipe command to be sent via RS-485 to start the timer cycle. Once the manual
wipe cycle has ended, the timed cycle will begin and the wiper will activate at the intervals set by DIP switches 6,7 & 8
accordingly. If the power supply to the VEGA
™
is cycled, a new RS-485 command will need to be sent to start the auto-wipe
timer again.