12-MENU ENTRIES AND OPERATION
SYSTEM CONFIGURATIONS
At the time of installation, the product must be configured according to the type of system by selecting the relative parameter in the
“SETTINGS” menu.
There are 5 possible configurations, described below:
Configuration
Description
1
Room temperature control via boiler's on-board probe or by enabling external thermostat.
2
2.1 Ambient temperature management with a probe fitted on the boiler or by enabling an external ambient
thermostat; instant production of hot sanitary water with plate exchanger in FACTORY CONFIGURATION.
2.2 Room temperature control via boiler's on-board probe or enabling external thermostat; DHW production for
storage cylinder or storage with thermostat (optional).
DISCONNECT THE INTERNAL THREE-WAY VALVE AND FLOW SWITCH (IF PRESENT)
3
Room temperature control via boiler's on-board probe or enabling external thermostat; DHW production with
NTC probe (10 kΩ ß3435).
DISCONNECT THE INTERNAL THREE-WAY VALVE AND FLOW SWITCH (IF PRESENT)
4
External Puffer controlled by thermostat.
5
External Puffer controlled by NTC probe (10 kΩ ß3435).
CONFIGURATION 1