12-MENU ENTRIES AND OPERATION
Technical Dept. - All rights reserved - Reproduction is prohibited
i - Auxiliary boiler
An additional module (optional) must be installed to allow the start-up of an auxiliary boiler when the main boiler is off or has been
stopped due to an alarm. By default, this function is deactivated (Off). If you need to activate it (On), go into the settings menu with key
5 and select the Auxiliary boiler option; confirm with key 5 and then with keys “b” (arrows) you can activate/deactivate the function (Off/
On). Key 5 is used to confirm, while key 8 is used to go back to the main screen.
j - Pellet Recipe
This function is for adapting the boiler to the type of pellet in use. As there are many types of pellet available on the market, the operation
of the boiler can vary considerably according to the quality of the fuel. When the pellets clog up the brazier due to excess loading of fuel
or when the flames are high even at low power, or when the flames are low, it is possible to decrease/increase the amount of pellets in
the brazier:
Available values:
A decrease of 30% on the factory setting.
A decrease of 20% on the factory setting.
A decrease of 10% on the factory setting.
0 = No changes.
An increase of 10% on the factory setting.
An increase of 20% on the factory setting.
An increase of 30% on the factory setting.
Use key 5 to go to the settings menu and select the Pellet Recipe option. Confirm with key 5 and then with keys “b” (arrows) you can
increase or reduce the %. Key 5 is used to confirm, while key 8 is used to go back to the main screen.
k - Fumes rpm % ventilation
In the event the installation presents problems in extracting smoke (lack of draft or even pressure in the duct), it is possible to increase
the smoke and ash extraction speed. This change resolves all the potential problems related to pellets clogging in the brazier and deposits
forming at the bottom of the brazier itself caused by poor quality fuel or fuel that produces a lot of ash. The extraction speed may be
altered between -30% to +50%, with increments of 10 percent at a time. Negative variation can be necessary if the flame is too low.