13-SAFETY DEVICES AND ALARMS
Technical Dept. - All rights reserved - Reproduction is prohibited
SAFETY DEVICES
The product is fitted with the following safety devices
PRESSURE SWITCH
Monitors pressure in the smoke duct. It is designed to shut down the pellet feed screw in the event of an obstructed flue or significant
back-pressure. (caused by wind)
SMOKE TEMPERATURE PROBE
Detects the temperature of the smoke, thereby enabling start-up or stopping the product when the temperature drops below the preset
value.
CONTACT THERMOSTAT IN THE FUEL HOPPER
If the temperature exceeds the preset safety level, it immediately shuts down the running of the boiler.
CONTACT THERMOSTAT IN THE BOILER
If the temperature exceeds the preset safety level, it immediately shuts down the running of the boiler.
WATER TEMPERATURE SENSOR
When the water reaches the stop temperature (85°C) the probe automatically instructs the boiler to turn off “OFF Stand-by”.
ELECTRICAL SAFETY
The boiler is protected against violent changes in current by a general fuse located in the control panel at the back of the boiler. Other fuses
that protect the electronic boards are found on the latter.
SMOKE FAN
If the fan stops, the electronic board shuts off the supply of pellets in good time, and an alarm message is displayed.
GEAR MOTOR
If the reduction motor stops, the boiler will continue to run until the flame goes out due to lack of fuel and until a minimum level of
cooling is reached.
TEMPORARY POWER CUT
When a power cut is less than 10” the boiler returns to its previous operating state; if it is more, it executes a cooling/re-ignition cycle.
FAILED START-UP
If the fuel fails to ignite during the start-up phase, the boiler will go into alarm status.
ANTI-FREEZE FUNCTION
If the probe in the boiler detects a water temperature of less than 5°C, the circulation pump is automatically activated to keep the system
from freezing.
PUMP ANTI-SEIZURE FUNCTION
If the pump is not used for prolonged periods, it is activated periodically for a few seconds to keep it from seizing up.
MICROSWITCH ON THE TROLLEY
The microswitch interrupts the launch of the cleaning system.
MICROSWITCH ON THE FIRE DOOR
The microswitch interrupts the launch of the cleaning and compressor system.
TAMPERING WITH THE SAFETY DEVICES IS PROHIBITED
If the product is NOT used as described in this instruction manual, the manufacturer declines all liability for any
damage caused to persons and property. The manufacturer furthermore refuses to accept responsibility for damage
to persons and property arising from the failure to observe all the rules contained in the manual and in particular:
• All the necessary measures and/or precautions must be adopted when performing maintenance, cleaning and
repairs.
• Do not tamper with the safety devices.
• Do not remove the safety devices.
• Connect the product to an efficient smoke expulsion system.
• First, check that the environment where it is to be installed is properly ventilated.
Only after having eliminated the cause of the intervention of the safety system is it possible to relight the product
and therefore restore the automatic operation of the probe. This manual will help you understand which anomaly
has occurred, and explain how to intervene according to the alarm message displayed on the appliance.