T7 Installation & User Manual
28
8. If the meters do not go green after 3 minutes, select the
BACK
button and return to the parameters
screen. Verify that your parameters are correct. If any changes are necessary, select OK when finished to
save the changes made.
Frequency
:
1242.5
Polarization
:
Horizontal
Chip Rate
:
20
Spectral Inversion
:
No
Spreading Factor
:
2
Orbital Position
:
093.1
(you must enter the ‘0’)
East/West
:
West
9. Once the signal bars have turned green and the padlock goes to the locked position, select
OK
on the
remote. A message will appear saying ‘This card is not authorized’ (Figure 12-3). Continue to the next
section for receiver activation procedures.
Figure 12-3 Receiver ready for activation