CONNECT THREE BUTTON STATION
Your operator has been supplied with a standard three button
station labeled open-close-stop. Mount three button station in
sight of the door, at a minimum height of 5 feet and away from
moving parts of the door. For proper connection of the three
button station refer to wiring diagram in lid of operator. At this
time also mount warning placard supplied in hardware box
next to three button station.
CONNECT ENTRAPMENT DEVICE
If other than constant pressure wiring type is required, you
must connect a photo electric control series 5000 by Vitector
Fraba, model HAE00056 by Linear Corp., or Miller Electric
reversing edge model ME with blue color band. For proper
connection of device, refer to wiring diagram found in lid of
operator.
WARNING: Failure to connect a Raynor approved
reversing device may cause severe injury or death.
WARNING: Do not let children operate the door or
play in the door area. Keep clear of the door it
may move at any time without warning and keep the door
in sight at all times when it is moving.
CONNECT TO POWER SUPPLY
WARNING: Before beginning any electrical
hook-up, disconnect quick release arm from
operator using quick release mechanism shown in
Fig. 8. Use caution when releasing trolley arm, it will
swing downward.
Consult local wiring codes prior to permanent installation.
This operator must be properly grounded. Refer to wiring
diagram, found on inside of control box cover, for power
line, push-button, and reversing device connections.
Verify that line voltage and operator voltage shown on the
cover are the same.
5973129-6
TO
PR
EV
EN
T
EN
TR
AP
ME
NT
Do
no
t
st
ar
t
do
or
do
wn
wa
rd
un
le
ss
do
or
wa
y
is
cl
ea
r
WA
RN
IN
G
W
AR
N
IN
G
ATTACH DOOR BRACKET
Some installations may require additional bracing
where door bracket is bolted to door. Fig. 7 shows
the type of bracing recommended by Raynor for the
Trolley Operator. Bracket should be located so holes
on door bracket line up with top rollers on door.
2 x 2 x 1/8 ANGLE
BY OTHERS
MUNTIN
DOOR BRACKET
BY RAYNOR
FIG. 7
TROLLEY CARRIAGE
DOOR BRACKET
CURVED ARM
QUICK RELEASE ARM
FIG. 8
ATTACH DRAWBAR Fig. 8
Move trolley carriage to within 6" of front mounting
bracket by manually turning large pulley at powerhead.
If operator is supplied with a brake, pull disconnect
bolt at back of brake mounting plate to disengage
brake.
Attach quick release arm to trolley carriage. With quick
release arm in vertical position, attach curved portion of
arm assembly to quick release portion using 5/16 x 1"
cap screws, nuts and lock washers furnished in hard-
ware package.
With door in fully closed position attach remaining end of
arm assembly to door bracket with 3/8 x 1" cap screw,
washers and nuts furnished. Arm should connect to door
bracket at hole nearest in line with top rollers of door. See
Fig. 8
Configuration:
Connect to
Sensor 1 Input
Connect to
Sensor 2 Input
Electric Edge Only
X
-
Photo Eye Only
X
-
Photo Eye & Electric Edge
Photo Eye
Electric Edge
Photo Eye & Photo Eye
Photo Eye 1
Photo Eye 2
Monitored Reversing Devices
WARNING: Install the Photo Eyes NO HIGHER than
6" (15cm) above the floor.
Note: When an external device, like a 3-button station,
motion detectors, or photo eyes are required, you must use
a wire type of CL2 or equivalent.