IMPORTANT INSTALLATION INSTRUCTIONS

WARNING - Failure to follow these precautions

may result in severe personal injury or death.

5973129-3

1.

READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.

2. Door must be installed properly and balanced before installing the operator. An improperly

     balanced door can be hazardous and cause severe injury. Repairs to cables, spring
     assemblies and other hardware must be made by a qualified door installer.
     Operator damage may result if installed on an improperly working door. Safety features of
     operator will not function properly if door is out of balance.

 3. Do not connect to electric power until installation is completed.

4. Remove or make inoperative any locking device unless operator is equipped with door lock

     interlock feature.

 5. Remove all ropes, step plates and lift handles connected to the door before operating the

     garage door operator.

6. Installation and wiring must conform to local building and electrical codes.

 7. Do not operate the transmitter or wall push-button unless the door is in sight.

8. Do not allow children to play with or in the area of the door and controls.

9. Do not place hands in area of pulleys, V-belt, sprockets, chain or rotating shafts.

10. Install warning placard on wall next to push-button.

11. Attach instruction booklet to wall near push-button.

12. Do not attempt to make electrical repairs without shutting off power to the unit.

13. Traffic patterns (vehicular and personnel) should be evaluated and proper safety equipment

      or push-button wiring installed to prevent damage or injuries.

14. Clutch should be adjusted according to procedure outlined on page 7 and checked
      periodically

15. Garage doors should

NEVER

be used as pedestrian doors.

16. Install the door operator at least 8 ft (2.44 m) or more above the floor. If the operator must be
      mounted less than 8 ft (2.44m) above the floor, the exposed moving parts must be protected
      by covers or guarding. Contact the manufacturer.

17. Verify that all labels for door and operator are in place, see page 18 for proper placement.

18. Install the Entrapment Warning Placard next to the door in a prominent location.

19. Locate the control station: (a) within sight of the door, (b) at a minimum height of 5 feet above

      floors, landings, steps, or any other adjacent walking surface and (c) away from all moving parts
      of the door.

20. For products having a manual release, instruct the end user on the proper operation of the
      manual release.

Содержание ControlHoist 2.0 STANDARD

Страница 1: ...ist 2 0 PLEASE READ THESE INSTRUCTIONS BEFORE STARTING INSTALLATION IT IS IMPORTANT THAT THIS OPERATOR BE INSTALLED CORRECTLY IN ORDER TO ACHIEVE SAFE AND PROPER OPERATION THIS OPERATOR HAS BEEN SUPPL...

Страница 2: ...replace the defective door components Labor charges for installations or repairs shall be the responsibility of the consumer and must be performed by an authorized Raynor Dealer This warranty extends...

Страница 3: ...s 9 Do not place hands in area of pulleys V belt sprockets chain or rotating shafts 10 Install warning placard on wall next to push button 11 Attach instruction booklet to wall near push button 12 Do...

Страница 4: ...ify delivering VISUAL INSPECTION carrier immediately rail assembly with lug B facing the open end of the rails ing packing material Unpack powerhead and trolley rail assemblies being 5973129 4 electri...

Страница 5: ...ng either lag screws or self tapping screws furnished in hardware package Resting powerhead of operator on floor attach front end of rails to front mounting bracket Swing unit into position over door...

Страница 6: ...e and operator voltage shown on the cover are the same 5973129 6 TO PRE VEN T ENT RAP MEN T Do not sta rt doo r dow nwa rd unle ss doo rwa y is clea r WAR NIN G W AR NING ATTACH DOOR BRACKET Some inst...

Страница 7: ...14 14 12 14 10 14 8 14 6 12 0 5 115 230 14 14 12 14 10 14 8 14 6 12 0 75 115 230 12 14 10 14 8 14 6 12 4 10 1 115 230 12 14 10 14 8 14 6 12 4 10 1 5 230 14 14 12 10 8 MINIMUM WIRE SIZE FOR SINGLE PHA...

Страница 8: ...minal Block 1 Terminal Block 2 High Voltage Wire Harness Connection LIGHT CCM NO1 SER C1NC1 NO2 C2NC2 ON OFF OPEN CLOSE ON OFF 24VDC 24VDC 24VAC 24VAC Terminal Block 3 24V DC Power Connection Auxiliar...

Страница 9: ...sing RD or RC wiring photo eye s or edge must be selected even though they are not required Note The photo eye or an electric edge must be monitored 5 SENSOR 2 TYPE will display there are three option...

Страница 10: ...OFF If a warning light is required select ON Press the stop button to continue 16 If a warning light is ON WARNING TIME will display The time is set in 1 second intervals from 3 seconds to 10 seconds...

Страница 11: ...r death 8 SAVE THESE INSTRUCTIONS OPERATING INSTRUCTIONS Operating the 3 Button Control Station 1 Press OPEN button The door should move in the open direction 2 Press STOP button The door should stop...

Страница 12: ...eck manual operation of door Refer to installation instructions 800 page 5972558 1 for guidelines Test all reversing devices once a month for proper operation Test all accessories that may have been s...

Страница 13: ...ng Off Stop button pressed or NOT connected On Open button sending signal pressed Off Open button is not sending signal 2 Open D12 6 I Lock D24 7 I Lock D23 On Chain hoist interlock circuit is open ch...

Страница 14: ...en limit switch and the open button is pushed This message will display anytime the board is not receiving a signal from the sensor 2 when close button is pressed Whether it is not connected activated...

Страница 15: ...minate stress on rollers and cables 1 Sunlight is blocking the receiving photo eye 2 Faulty photo eyes 1 Connect Operator to power source 2 Check voltage at L1 L2 for single phase and at L1 L2 L3 for...

Страница 16: ...oard Verify power consumption of the device s before installing You may have to power the device from an external power source using only the contacts of the device to activate the operator 3 The comm...

Страница 17: ...use the dry contacts of that relay to activate the device If more than 3 amps of power is being consumed through the auxiliary board then damage to the board may occur 2 There is a 14 pin connector o...

Страница 18: ...lied With Raynor Door NOTE Placement of Labels may vary from what is shown Spring Warning Tag Push Button Placard Locate Near Push Button Door Safety Label Bottom Fixture Danger Label Bottom Fixture D...

Отзывы: