55M4500CCE00 REV A
A list of files will be displayed, either
“xxxx.cf”
or
“xxxx.cal”
depending on the choice
above. Note that only files located in the root folder of the USB stick will be displayed.
Select the relevant file from the list displayed and press
“
”
, the selected file will be
copied to the i4500 system and will replace any existing data.
Once done, it is advisable to reboot the system (power off and on again) and reselect a
valid configuration,
do not
accept the existing default duty presented on start up.
“Memory”
Warning:
Initialising memory A will delete all the information stored in the calibration
memory, be sure you have made a backup copy of the calibration file before using this
option –
if in doubt, don’t!
initialize memories A and C
Select this option to re‐initialize the system memory, a warning screen will be displayed
to ask for confirmation, if confirmed all calibration data will be deleted.
initialize memory C
Select this option to re‐initialize the memory for the current configuration, only data
related to the current operator settings will be deleted ie duty number, parts of line
settings etc. Reset the duty configuration immediately after initializing memory C.