![background image](http://html.mh-extra.com/html/raven/scs-460/scs-460_operators-manual_788837008.webp)
5
2.
MOUNTING THE FLOW METER AND OPTIONAL PRESSURE
TRANSDUCER
FLOWMETER
1)
Mount Flow Meter in the area of the boom valves per
Figure 4
. All flow through
Flow Meter must go to booms only, i.e., no return line to tank or pump after Flow
Meter.
2)
Mount Flow Meter horizontal to the ground. Use the bracket to secure the Flow
Meter.
3)
For best results, allow a minimum of 7 1/2 inches [20 cm] of straight hose on inlet
of Flow Meter. Bend radius of hose on outlet of Flow Meter should be gradual.
4)
Flow must be in direction of arrow on Flow Meter.
FIGURE 4
FIGURE 4
FIGURE 4
FIGURE 4
FIGURE 4
NOTE:It is essential, when using suspensions, that the system be thoroughly
rinsed out each day after use.
OPTIONAL PRESSURE TRANSDUCER
1)
Mount optional pressure transducer, part #422-0000-059, on desired location.
Use cables 115-0171-152 (or 115-0171-153)and 115-0171-151.
2)
With pump turned off and 0 PSI [kPa] on the lines, enter 0 for pressure calibration
(cal pressure) under Data Menu Key.
3)
When system is operating, system PSI [kPa] will be displayed when the
or
key is depressed.