11
EXAMPLE:
Assume DISTANCE reads 5000 [980].
Corrected SPEED CAL
=
Old SPEED CAL x 5280
DISTANCE
ENGLISH UNITS:
METRIC UNITS:
= 598 x 5280 = 631.48
= [152] x [1000] = [155]
5000
[980]
The number to enter for SPEED CAL is 631 [155].
5)
Enter the number calculated for SPEED CAL.
6)
Recheck the new SPEED CAL derived in Step 5 by repeating Steps 2 thru 5.
3.
CALCULATING "METER CAL"
The Flow Meter calibration number is stamped on the tag attached to each Flow Meter.
Write down this number for future reference when programming the Console.