REMOTE COMPUTER TO SCS 450/460 CONSOLE
All request strings begin with $R, to indicate a Raven communication string.
Rate 1 Change Request:
$R,RC,<rate_1_cal><CR><LF>
Calibration String Values Request:
$R,CR<CR><LF>
Data String Request:
$R,DR<CR><LF>
SCS 450/460 CONSOLE TO REMOTE COMPUTER
All console output strings begin with $R124F, the $R indicates a Raven
communication string, the 124 is the last three digits of the current SCS 450/
460 programmed chip part number and F is the software revision number.
Calibration Strings:
$R124F,C1,<switch_byte_1>,<switch_byte_2>,<boom_1_cal>,
<boom_2_cal>,<boom_3_cal>,<boom_4_cal>,<boom_5_cal>,
<boom_6_cal>,<boom_7_Cal>,<speed_cal> <CR><LF>
$R124F,C2,<meter_cal>,<CR><LF>
$R124F,C3,<valve_cal>,<rate_1_cal>,<rate_2_cal><CR><LF>
Bit
Switch Byte 1
Switch Byte 2
0
boom
1
0
1
boom
2
0
2
boom
3
0
3
boom
4
rate 1
4
boom
5
rate 2
5
boom
6
0
6
boom
7
0
7
1
1
Data Strings:
$R124F,D1,<total_area>,<field_area><CR><LF>
$R124F,D2,<total_volume>,<field_volume><CR><LF
$R124F,D3,<tank_volume>,<distance><CR><LF>
Actual Rate:
$R124F,AR,<actual_rate><CR><LF>
Time/Date:
$R124F,TD,<hr:min>,<month/day/year>,<field_reference><CR><LF>
APPENDIX 7
SCS 460 COMMUNICATION STRINGS
NOTE: If rate 1 and rate 2 are both zero,
the console is in Manual. For switch Byte
Bits; 0 = off and 1 = on.