Troubleshooting: Diagnostic Trouble Code (DTC) List
67
TROUBLESHOOTING
523193
.16
High system efficiency
1. Check the plumbing system for leaks.
2. Check the pressure transducer type selected.
3. Check the flow meter calibration value.
4. Verify the fence row outputs are not active.
5. Check the NCV2s for debris or seal for wear.
.18
Low system efficiency
1. Check the pressure transducer type selected.
2. Check the flow meter calibration value.
3. Check the NCV2s for debris or seal
deformation.
523520
.31
Invalid flow meter calibration
1. Enter a valid flow meter calibration value.
523906
.17
Equipment speed below the
speed range (single NCV2)
1. Increase equipment speed to the range
displayed on the RCM - Sprayer home screen.
section on page 48 for assistance with
the information provided on the home
screen.
523907
.17
Equipment speed below the
speed range (multiple NCV2s)
1. Increase equipment speed to the range
displayed on the RCM - Sprayer home screen.
523908
.15
Equipment speed above the
speed range (single NCV2)
1. Reduce equipment speed to the range
displayed on the RCM - Sprayer home screen.
523909
.15
Equipment speed above the
speed range (multiple NCV2s)
1. Reduce equipment speed to the range
displayed on the RCM - Sprayer home screen.
section on page 48 for assistance with
the information provided on the home
screen.
523910
.31
NCV2 power/temperature
error (single)
1. Check for clogs in valve or associated
plumbing that may be preventing liquid flow
through the valve.
523911
.31
NCV2 power/temperature
error (multiple)
1. Check for restrictions in valves or associated
plumbing that may be preventing liquid flow
through the valve.
523912
.31
NB voltage low single
1. Reduce operating speed.
2. Verify the NCV2 voltage is above 10.5 V.
3. Check the system cabling for damage.
4. Check the NCV2 duty cycle for proper
operation.
5. Contact a local Raven dealer if the issue is not
resolved.
523913
.31
NB voltage low multi
1. Reduce operating speed.
2. Verify the NCV2 voltage is above 10.5 V.
3. Check the system cabling for damage.
4. Check the NCV2 duty cycle for proper
operation.
5. Contact a local Raven dealer if the issue is not
resolved.
Code ID
Description
Recommended Actions
Содержание RCM-Sprayer Hawkeye 2
Страница 6: ...TABLE OF CONTENTS iv RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 10: ...CHAPTER 1 viii RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 20: ...CHAPTER 2 10 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 28: ...CHAPTER 3 18 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 52: ...CHAPTER 5 42 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 60: ...CHAPTER 6 50 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 66: ...CHAPTER 8 56 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 90: ...APPENDIX A 80 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 94: ...APPENDIX B 84 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 107: ... Boom Harness Connector Maintenance 97 FIGURE 3 Applying Corrosion Inhibitor NCV2 Connector Corrosion Inhibitor Applied ...
Страница 108: ...APPENDIX D 98 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 120: ...APPENDIX F 110 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...