4
System Setup: Applicator Setup Tab
23
SYSTEM SETUP
Select Tip and Tip Name.
Use the drop-down list to:
a. set up a new spray tip that will be used with the system
b. select a spray tip previously set up
Enter a name (up to 12 characters) for the tips to allow the operator to quickly select the appropriate spray tips
for the field application.
NOTE:
The tip size profile will display as “---” if the NCV2 or bypass tip size is not editable based upon the
selected NCV2 control mode.
NCV2 Tip Size.
Select the size of the spray tips installed on the Hawkeye® 2 NCVs.
Droplet Size.
Enter the published information available from the tip manufacturer for the tip size and series.
Minimum/Maximum Pressures.
Enter the pressure range (minimum and maximum) for the spray tips installed to
help maintain the desired droplet sizing.
NOTE:
When entering pressure ranges for different droplet size classifications, ensure that the values
entered are within the overall minimum and maximum spray pressure range set in the Pressure Setup
Menu.
TEST SPEED
The Test Speed feature allows the operator to enter a simulated speed for the system and allows the operator to
check and verify system operation and functionality while the equipment remains stationary.
To enter a test speed:
NOTE:
A test speed may also be entered via the Speed Readout on the Home page. Refer to the
section on page 28 for assistance with customizing the Home tab displays.
1. Open the UT Menu and select the RCM - Sprayer Menu button.
2. Select the Tools Menu softkey along the right side of the display.
3. Select the Applicator Setup tab along the top of the display.
4. Select the Test Speed button. The Test Speed page will be displayed.
5. Either enter the desired simulated speed or select the Resume Last Speed button to set the speed for testing
system operation.
NOTE:
Enter a test speed that is within the acceptable speed range for the system as setup. Entering a test
speed above or below the recommended speed range may cause pressures outside of the operation
range and may result in alarms or product shut down.
RCM - Sprayer Menu
Tools Menu
Applicator
Setup
UT Menu
Test Speed
Содержание RCM-Sprayer Hawkeye 2
Страница 6: ...TABLE OF CONTENTS iv RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 10: ...CHAPTER 1 viii RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 20: ...CHAPTER 2 10 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 28: ...CHAPTER 3 18 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 52: ...CHAPTER 5 42 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 60: ...CHAPTER 6 50 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 66: ...CHAPTER 8 56 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 90: ...APPENDIX A 80 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 94: ...APPENDIX B 84 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 107: ... Boom Harness Connector Maintenance 97 FIGURE 3 Applying Corrosion Inhibitor NCV2 Connector Corrosion Inhibitor Applied ...
Страница 108: ...APPENDIX D 98 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 120: ...APPENDIX F 110 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...