CHAPTER 4
28
RCM - Sprayer and Hawkeye® 2 Calibration and Operation Manual
CURRENT TANK LEVEL
Manually set or adjust the product volume in the tank. This feature may be useful to manually set the tank level if
products are added through the top of the tank, to correct the volume for a known amount of product added to
the tank, or to adjust the tank level to a different value other than the full tank capacity.
Either enter the current tank level manually upon refilling the tank or use the tank fill flow meter to automatically
measure the amount of product added to the tank.
LOW TANK LEVEL AND LOW TANK ALARM
Enter the low tank threshold to provide an indicator at the level which the tank is nearing empty. If the Alarm
option is enabled for the low tank threshold, an audible alarm will be activated when the calculated volume
remaining in the tank reaches the set threshold.
PRODUCT TYPE
Select Water-Based or Fertilizer for the type of product applied. The system will compensate for the different flow
characteristics of each liquid.
NOTE:
The meter cal may need to be adjusted when changing product types. Refer to the
MAX TANK FILL PWM
Set the maximum desired output for the tank fill pump controlled by a pulse width modulated (PWM) hydraulic
control valve. This setting limits how far the PWM valve will open.
DISPLAY SETUP MENU
The machine operator may customize the readouts displayed on each product rate control tab and the pressure
tab shown on the Home page.
FIGURE 1. Home Page Display Tabs
To customize the information displayed on the Home page of RCM - Sprayer system:
1. Open the UT Menu and select the RCM - Sprayer Menu button.
2. Select the Tools Menu softkey along the right side of the display.
3. Select the System Settings tab along the top of the display.
4. Select the Display Setup Menu button on the System Settings page. The Display Setup page is displayed.
Pressure Display
Tab
Product Rate
Control Tab
RCM - Sprayer Menu
Tools Menu
System
Settings
UT Menu
Display
Setup Menu
Содержание RCM-Sprayer Hawkeye 2
Страница 6: ...TABLE OF CONTENTS iv RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 10: ...CHAPTER 1 viii RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 20: ...CHAPTER 2 10 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 28: ...CHAPTER 3 18 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 52: ...CHAPTER 5 42 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 60: ...CHAPTER 6 50 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 66: ...CHAPTER 8 56 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 90: ...APPENDIX A 80 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 94: ...APPENDIX B 84 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 107: ... Boom Harness Connector Maintenance 97 FIGURE 3 Applying Corrosion Inhibitor NCV2 Connector Corrosion Inhibitor Applied ...
Страница 108: ...APPENDIX D 98 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 120: ...APPENDIX F 110 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...