APPENDIX E
100
RCM - Sprayer and Hawkeye® 2 Calibration and Operation Manual
completed, the ISO icon at the top right of the screen will be green. Hawkeye® 2 NCVs must be properly
indexed for this to work.
8. Ensure there are no active DTCs. Review the
section on page 45 for assistance with the DTC status
indicator if necessary.
NOTE:
If there is water in the tank, the following steps may be performed with the engine running and the
product pump enabled. Do not run the pump for an extended period of time with no liquid in the
tank as this may damage the pump.
If the product pump is not enabled, the system will encounter a pump pressure error.
9. Enter a test speed in the UT mode. The boom section display on the Home page should respond with the
corresponding section icons in the UT window.
•
No triangle indicates that the section is off
•
an empty triangle indicates the section is active but is being controlled by automatic section
control.
•
A triangle that is filled in blue indicates the section is spraying.
NOTE:
The NCV2s will emit an audible clicking noise while operating properly.
10. Start a job. Ensure that all necessary widgets are available to the operator to allow proper machine operation.
Make a copy for the complete widget setup for the operator to modify.
11. In job view mode, enter a test speed. Verify that the section control is off. The boom section display on the
Home page should respond with the corresponding section icons in the UT window.
•
No triangle means the boom is off.
•
An empty triangle indicates the boom is active but is being controlled by automatic section control.
•
A triangle filled in blue means the boom should be spraying. Expect a pump pressure error since
the pump is not running. if the booms do not respond correctly, delete and import the boom
settings.
12. Once the system is functioning properly, fill the tank with water and complete the functional inspection.
FUNCTIONAL INSPECTION
Refer to the following sections for assistance with validating that the Hawkeye® 2 system has been installed
properly:
NOZZLE CONTROL VALVE FUNCTION
To verify that the Hawkeye® 2 system is functioning properly after installation:
1. Flush the main product tank and boom plumbing with clean water, and verify the tank contains at least 100
gallons [379 L] of clean water.
2. Park the equipment in an area with enough space to unfold the booms and allows for visual inspection of the
spray pattern from a moderate distance (e.g. 20 ft [6.1 m]).
3. Set the Hawkeye® 2 system to manual mode, and set both the pump PWM and NCV2 PWM to 50%. Refer to
section on page 47 for assistance with adjusting the PWM percent values in the manual
control mode.
Содержание RCM-Sprayer Hawkeye 2
Страница 6: ...TABLE OF CONTENTS iv RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 10: ...CHAPTER 1 viii RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 20: ...CHAPTER 2 10 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 28: ...CHAPTER 3 18 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 52: ...CHAPTER 5 42 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 60: ...CHAPTER 6 50 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 66: ...CHAPTER 8 56 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 90: ...APPENDIX A 80 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 94: ...APPENDIX B 84 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 107: ... Boom Harness Connector Maintenance 97 FIGURE 3 Applying Corrosion Inhibitor NCV2 Connector Corrosion Inhibitor Applied ...
Страница 108: ...APPENDIX D 98 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 120: ...APPENDIX F 110 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...