CHAPTER 9
66
RCM - Sprayer and Hawkeye® 2 Calibration and Operation Manual
523091
.1
NCV2 calibration error
(multiple)
1. Cycle system power.
2. Edit profile.
3. Contact a local Raven dealer for additional
assistance.
523092
.31
No tip information entered
for nozzle control valve
(single)
1. Select the appropriate tip type. Refer to the
additional assistance.
2. Edit the profile to reset the tip type setting for
the nozzle control system.
523093
.31
No tip information entered
for nozzle control valves
(multiple)
1. Select the appropriate tip type. Refer to the
additional assistance.
2. Edit the profile to reset the tip type setting for
the nozzle control system.
523126
.13
Unable to detect RCM -
Sprayer ECU orientation
1. Check the RCM - Sprayer ECU mounting
position and verify the RCM - Sprayer ECU is
securely mounted.
2. Recalibrate the RCM - Sprayer ECU gyro.
523136
.16
Monitored flow rate is higher
than the target rate deadband
1. Reduce the equipment speed.
2. Review
Avoiding Skips with Hawkeye® 2
3. Refer to the
on page 46 for assistance with setting or
adjusting the target rate.
4. Refer to the
page 36 for assistance with setting or
adjusting the off rate percent.
.18
Monitored flow rate is lower
than the target rate deadband
1. Increase the equipment speed.
2. Refer to the
on page 46 for assistance with setting or
adjusting the target rate.
3. Refer to the
page 36 for assistance with setting or
adjusting the off rate percent.
523137
.18
Minimum flow not met
1. Activate product pump.
2. Review
Avoiding Skips with Hawkeye® 2
3. Increase pump output to maintain the
minimum recommended flow rate for each
nozzle control valve.
523192
.14
New injection pump detected
1. Edit Profile or New Profile to configure the
injection pump as a product.
.15
Injection pump lost
communication
1. Verify the LEDs on the injection pump are on.
2. Check the CAN connections of the injection
device.
3. Connect the Raven Service Tool to the
ISOBUS and verify communication.
Code ID
Description
Recommended Actions
Содержание RCM-Sprayer Hawkeye 2
Страница 6: ...TABLE OF CONTENTS iv RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 10: ...CHAPTER 1 viii RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 20: ...CHAPTER 2 10 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 28: ...CHAPTER 3 18 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 52: ...CHAPTER 5 42 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 60: ...CHAPTER 6 50 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 66: ...CHAPTER 8 56 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 90: ...APPENDIX A 80 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 94: ...APPENDIX B 84 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 107: ... Boom Harness Connector Maintenance 97 FIGURE 3 Applying Corrosion Inhibitor NCV2 Connector Corrosion Inhibitor Applied ...
Страница 108: ...APPENDIX D 98 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 120: ...APPENDIX F 110 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...