System Setup: System Settings Tab
35
SYSTEM SETUP
GROUP END NCV2S
NOTE:
Not available in the Bypass NCV2 control mode.
Enable this option to link the three NCV2s at the end of the boom to the NCV2 immediately beside them. When
one of the NCV2s are turned on, all linked NCV2s will turn on. This feature may be helpful in areas with poor GPS
coverage to prevent the end NCV2s from flickering on and off.
QUICK START SECONDS
Enter the number of seconds to override sections status after the automatic section control override feature is
enabled. When the quick start is enabled, any sections set to automatic control will turn on for the time entered as
the quick start seconds value.
NOTE:
Any sections set for manual control, or toggled on or off manually, will not be affected by the quick
start seconds feature.
This feature may be useful to start application with the equipment at a complete stop or to manually override
sections on for a brief time.
NOTE:
The default quick start seconds value is 15 seconds. The quick start seconds value may only be
changed without an active application in progress. If a Raven Viper 4 field computer is installed with
the system, the operator may use the on-screen widget to change the override seconds.
Quick start will only activate sections set for automatic section control. Any sections configured for
manual control, or set on or off manually, will not be affected by the quick start feature.
WIRELESS CONTROL MODE
The wireless control mode enables the machine operator to perform system checks and maintenance outside of
the cab using a BLUETOOTH
®
Low Energy device such as a Bluetooth enabled mobile device or the Raven Remote
Section Control 2.0 (P/N 063-0174-001). Select one of the following modes for the wireless control feature:
Off.
(Default) Turn off wireless control and disable remote access to the RCM - Sprayer system.
Section.
The operator may use a connected wireless remote device to control boom section valves and NCV2s
associated with each boom section.
NCV.
This mode will allow a compatible wireless remote device to control individual NCV2s.
PUMP RPM CALIBRATION
Pump RPM Calibration.
Sets the number of pulses per revolution of the pump if a speed sensor is installed on
the pump.
Pump RPM Minimum and Maximum.
Sets the rotational speed range of the pump.
Содержание RCM-Sprayer Hawkeye 2
Страница 6: ...TABLE OF CONTENTS iv RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 10: ...CHAPTER 1 viii RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 20: ...CHAPTER 2 10 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 28: ...CHAPTER 3 18 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 52: ...CHAPTER 5 42 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 60: ...CHAPTER 6 50 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 66: ...CHAPTER 8 56 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 90: ...APPENDIX A 80 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 94: ...APPENDIX B 84 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 107: ... Boom Harness Connector Maintenance 97 FIGURE 3 Applying Corrosion Inhibitor NCV2 Connector Corrosion Inhibitor Applied ...
Страница 108: ...APPENDIX D 98 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Страница 120: ...APPENDIX F 110 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...