Retractable Flap Barrier Operation Manual
22
- -
NP01: Device type selection
00: blocking; 01: logic to determine the Retractable Flap Barriers;
02:; 03:;
04: single Retractable Flap Barriers; 05:;
NP02: Parameter recovery
When the display shows ‘NP02’, press SET to enter and display the P-H value.
Press and hold INC when you need to restore the default value.
Or the DEC button for about 2 seconds. When the P-F is displayed, the parameter
is successfully restored. After the setting is completed, press the SET button to
save the setting value and exit the setting.
Go back to setup mode.
NP03: default; NP04: default; NP05: default; NP06: post-delay function
00: not open; 01: open;
NP07: Gate is reversed
00: forward; 01: reverse;
NP08: Device reduction ratio setting
This value is calculated as the motor gearbox reduction ratio *output gear
reduction ratio /15
NP09: Main and auxiliary settings
00: host mode; 01: slave mode
9.
Frequently asked questions
Retractable Flap Barriers debugging steps
1. Fixed limit plate (the magnet should be installed under the limit plate when