Retractable Flap Barrier Operation Manual
20
- -
●
02: Alarm for the buzzer.
LP04: default
LP05: default
LP06: Pass time
The value is 3-60, in seconds
LP07 : Signal effective time
The value is 10-50 in seconds
LP08: device address
The value is 0-255;
LP09: extraordinary delay time
The value is 0-60;
The following menus have parameters for the main sub-control board:
dP01: maximum operating speed of the gate
The value is 0-16; the higher the value, the higher the startup speed;
dP02 : collision speed setting:
The value is 0-16; the larger the value, the greater the return strength;
dP03 : Retractable Flap Barriers zero is set: operate according to voice;
dP04 : Gate off 1 Fine adjustment
Refer to the slave control panel display (CLO1) when adjusting this parameter;
The value is 0-50;
dP05 : Gate off 2 Fine adjustment